2008
DOI: 10.3155/1047-3289.58.11.1474
|View full text |Cite
|
Sign up to set email alerts
|

Whole House Particle Removal and Clean Air Delivery Rates for In-Duct and Portable Ventilation Systems

Abstract: A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the ab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
53
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 50 publications
(55 citation statements)
references
References 1 publication
2
53
0
Order By: Relevance
“…Although this method is valid, it is time consuming and they estimated the experimental uncertainty to be approximately 20% or more. MacIntosh et al (2008) simply assumed that airflow rates remained constant with each filter, an unlikely assumption for the range of filters tested and the types of systems in most residential and light-commercial systems (Stephens et al 2010a(Stephens et al , 2010b. The flow plate device that we used has been shown to be more accurate than previous methods and is relatively quick to use (Francisco and Palmiter 2003).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Although this method is valid, it is time consuming and they estimated the experimental uncertainty to be approximately 20% or more. MacIntosh et al (2008) simply assumed that airflow rates remained constant with each filter, an unlikely assumption for the range of filters tested and the types of systems in most residential and light-commercial systems (Stephens et al 2010a(Stephens et al , 2010b. The flow plate device that we used has been shown to be more accurate than previous methods and is relatively quick to use (Francisco and Palmiter 2003).…”
Section: Discussionmentioning
confidence: 99%
“…The whole-house test methods in Offermann et al (1992), Howard-Reed et al (2003), Wallace et al (2004), and MacIntosh et al (2008) were refined for the purposes of this work. The method consists of the same general practices: artificially elevating indoor particle concentrations and measuring the subsequent concentration decay with and without a filter installed in the operating HVAC system, while simultaneously measuring the AER through the building by tracer gas decay.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The efficiency, removal rates, and other performance characteristics of some of these devices have been characterized empirically (Chen et al, 2006;Shaughnessy and Sextro, 2006;MacIntosh et al, 2008). The potential for advanced filtration technology to mitigate indoor exposure to PM 2.5 of ambient origin in Europe was estimated from results of the EXPOLIS study (Hanninen et al, 2005).…”
Section: Introductionmentioning
confidence: 99%