2023
DOI: 10.1007/s12551-023-01055-8
|View full text |Cite
|
Sign up to set email alerts
|

Whole-cell patch-clamp recording and parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 96 publications
0
5
0
Order By: Relevance
“…We here introduce loose-patch clamp methods ( Stühmer et al, 1983 ) to investigate corresponding effects in native in situ CA1 pyramidal neurons in hippocampal coronal slices for the first time. This approach complements conventional tight patch electrode techniques previously used in both on- and whole-cell electrophysiological single-cell current-clamp ( Liu et al, 2001 ; Minlebaev et al, 2013 ; Ghasemi et al, 2018 ; Vazetdinova et al, 2022 ) or voltage-clamp studies of neuronal cells in hippocampal tissue slices ( Kodirov, 2023 ) or following isolation ( Mathias et al, 1990 ; Klee et al, 1995 ). However, on the one hand, the whole-cell conventional patch clamp configuration permitting membrane current measurement over the entire somal cell membrane involves cell membrane rupture to electrically access the intracellular environment ( French et al, 1990 ).…”
Section: Introductionmentioning
confidence: 90%
“…We here introduce loose-patch clamp methods ( Stühmer et al, 1983 ) to investigate corresponding effects in native in situ CA1 pyramidal neurons in hippocampal coronal slices for the first time. This approach complements conventional tight patch electrode techniques previously used in both on- and whole-cell electrophysiological single-cell current-clamp ( Liu et al, 2001 ; Minlebaev et al, 2013 ; Ghasemi et al, 2018 ; Vazetdinova et al, 2022 ) or voltage-clamp studies of neuronal cells in hippocampal tissue slices ( Kodirov, 2023 ) or following isolation ( Mathias et al, 1990 ; Klee et al, 1995 ). However, on the one hand, the whole-cell conventional patch clamp configuration permitting membrane current measurement over the entire somal cell membrane involves cell membrane rupture to electrically access the intracellular environment ( French et al, 1990 ).…”
Section: Introductionmentioning
confidence: 90%
“…We here introduce loose patch clamp methods to investigate particular features of membrane current in CA1 cells in hippocampal slices for the first time. This complements conventional tight patch electrode techniques proven to be invaluable in both on‐ and whole‐cell electrophysiological single cell current‐clamp 9–12 or voltage‐clamp studies of neuronal cells in hippocampal tissue slices 13 or following isolation 14,15 . The latter techniques utilize electrodes with relatively small tip diameters to achieve required high seal resistances 16,17 .…”
Section: Introductionmentioning
confidence: 94%
“…Rounding out the Issue is a scientific letter contributed by a scientist based in Austria (Kodirov 2023) who discusses different aspects of the patch clamp method-an electrophysiological procedure capable of inferring differences in conduction at the single ion channel level. Starting with a general outline of the technique, this scientific letter relates different aspects of the experimental setup to both expected and anomalous observations at the level of recorded current and electrochemical potential (Kodirov 2023). Having provided this short summary of the current Issue's contents, we round out this Editorial with a short discussion of the pros and cons of writing in both, the formulation of ideas, and in their understanding.…”
Section: Precis Of the Current Issuementioning
confidence: 99%