2007
DOI: 10.1007/s00216-007-1770-5
|View full text |Cite
|
Sign up to set email alerts
|

Whole-cell luminescence-based flow-through biodetector for toxicity testing

Abstract: A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including "top cover" to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 29 publications
(10 citation statements)
references
References 14 publications
0
10
0
Order By: Relevance
“…Thus it could be a case where the light intensity produced by a microbe would decrease on interaction with a toxic compound. A Vibrio fi scheri -based microbial biosensor was developed on the same principle for the determination of toxicity of some common environmental pollutants in a continuous fl ow system (Stolper et al 2008 ). A bioluminescent biosensor using Pseudomonas fl uorescens HK44 pUTK21 recognition element has been designed to detect the available fraction of naphthalene in soil since there was a linear relationship between the luminescence from the microbe and naphthalene concentration (Paton et al 2009 ).…”
Section: Bioluminescent Microbial Biosensormentioning
confidence: 99%
“…Thus it could be a case where the light intensity produced by a microbe would decrease on interaction with a toxic compound. A Vibrio fi scheri -based microbial biosensor was developed on the same principle for the determination of toxicity of some common environmental pollutants in a continuous fl ow system (Stolper et al 2008 ). A bioluminescent biosensor using Pseudomonas fl uorescens HK44 pUTK21 recognition element has been designed to detect the available fraction of naphthalene in soil since there was a linear relationship between the luminescence from the microbe and naphthalene concentration (Paton et al 2009 ).…”
Section: Bioluminescent Microbial Biosensormentioning
confidence: 99%
“…A HPLC method has been online hyphenated to a chemical assay (i.e., a DPPH free radical scavenging assay) [7,8], and even to enzymic assays (i.e., a cholinesterase inhibitory assay) [9,10]. In regard to bacterial cell assays, only Aliivibrio fischeri bacteria cells have been introduced directly to HPLC effluent [11], although the cell death increased with the amount of methanol in the eluent. Hyphenation of these methods using HPLC leads to the dilution of analytes with reagents and the use of long reaction coils resulting in extra peak broadening [9].…”
Section: High Performance Thin Layer Chromatography/thin Layer Chromamentioning
confidence: 99%
“…A Vibrio fi scheri -based microbial biosensor was developed on the same principle for the determination of toxicity of some common environmental pollutants in a continuous fl ow system (Stolper et al 2008 ). Thus it could be a case where the light intensity produced by a microbe would decrease on interaction with a toxic compound.…”
Section: Bioluminescent Microbial Biosensormentioning
confidence: 99%