Whole-body radiofrequency coil for31P MRSI at 7 T

Abstract: Widespread use of ultrahigh-field (31) P MRSI in clinical studies is hindered by the limited field of view and non-uniform radiofrequency (RF) field obtained from surface transceivers. The non-uniform RF field necessitates the use of high specific absorption rate (SAR)-demanding adiabatic RF pulses, limiting the signal-to-noise ratio (SNR) per unit of time. Here, we demonstrate the feasibility of using a body-sized volume RF coil at 7 T, which enables uniform excitation and ultrafast power calibration by pick-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
42
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(44 citation statements)
references
References 46 publications
(78 reference statements)
2
42
0
Order By: Relevance
“…B 1 + field homogeneity was assessed from designs by Löring as our design is merely scaled to the bore size. The homogeneity of the insert was shown from the use of B 1 maps from 3 T proton MRI, which have identical diameter and coil layout to the present 31 P body coil and are tuned to almost the same frequency …”
Section: Discussionsupporting
confidence: 81%
See 3 more Smart Citations
“…B 1 + field homogeneity was assessed from designs by Löring as our design is merely scaled to the bore size. The homogeneity of the insert was shown from the use of B 1 maps from 3 T proton MRI, which have identical diameter and coil layout to the present 31 P body coil and are tuned to almost the same frequency …”
Section: Discussionsupporting
confidence: 81%
“…19 In another recent publication, Löring et al showed an insertable 31 P birdcage body coil that can produce uniform B 1 fields, thus allowing the use of rectangular RF pulse excitations. 20 This birdcage coil is wide enough to accommodate the human torso, allowing 31 In this work, we demonstrate that the permanent installation of a 31 P body coil behind the covers of the patient tube, ie without sacrificing patient space, while interfacing to a high power RF amplifier, increases its usability. The reduction in SAR with this body coil allows the use of rectangular and even multiple rectangular composite pulses.…”
Section: Introductionmentioning
confidence: 80%
See 2 more Smart Citations
“…The combination of the receive sensitivity of modern coil-arrays with the transmit power, B 1 homogeneity, and volume coverage of volume coils, e.g., the recently proposed volume coil for 7 T [28], could, in the future, constitute a prime tool for 31 P-MR at ultra-high fields.…”
Section: Introductionmentioning