2007
DOI: 10.1055/s-2007-972138
|View full text |Cite
|
Sign up to set email alerts
|

Whole body 3T MRI system with eight parallel RF transmit/receive channels and dual operation modes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
26
0

Year Published

2007
2007
2010
2010

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(28 citation statements)
references
References 0 publications
0
26
0
Order By: Relevance
“…Each bottle had a square cross-section of 5 Â 5 cm 2 , yielding an overall phantom size of 25 Â 25 cm 2 . This phantom was used to determine the spatial transmit sensitivity distributions S n (r) of the N ¼ 8 elements of a multichannel body coil (20), integrated in a Philips 3T Achieva (Philips Medical System, Best, The Netherlands) (13). The transmit sensitivities were measured by actual flip angle imaging (17), including RF spoiling (21) (TR1/ TR2/echo time ¼ 40/200/2 ms, a ¼ 60 , spatial resolution 20 Â 20 Â 10 mm 3 ).…”
Section: Determination Of Encoding Functionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Each bottle had a square cross-section of 5 Â 5 cm 2 , yielding an overall phantom size of 25 Â 25 cm 2 . This phantom was used to determine the spatial transmit sensitivity distributions S n (r) of the N ¼ 8 elements of a multichannel body coil (20), integrated in a Philips 3T Achieva (Philips Medical System, Best, The Netherlands) (13). The transmit sensitivities were measured by actual flip angle imaging (17), including RF spoiling (21) (TR1/ TR2/echo time ¼ 40/200/2 ms, a ¼ 60 , spatial resolution 20 Â 20 Â 10 mm 3 ).…”
Section: Determination Of Encoding Functionsmentioning
confidence: 99%
“…To resolve two spatial dimensions via backprojection-like techniques, a rotation of the object (5), a rotation of the surface transmit coil around the object (7), or the application of orthogonal RF gradients (6,8) was proposed. Parallel transmit systems (11)(12)(13)(14), supporting multiple individual transmit channels, facilitate the mentioned rotations in an electronic, nonmechanical manner. This new hardware concept, originally developed to cope with spatial B 1 inhomogeneities, can find interesting applications in RF encoding and might enable even three-dimensional spatial resolution.…”
mentioning
confidence: 99%
“…107 Left: Transmit-receive RF coil with eight cylindrically arranged transverse electromagnetic elements, 105 and quality phantom. Center: Corresponding cabinets showing eight RF amplifiers, two circulator boxes (central cabinet) and the fully integrated spectrometer (right cabinet).…”
Section: Figmentioning
confidence: 99%
“…More recently, researchers have designed eight-channel parallel excitation systems and demonstrated slice-selective and 2D spatial excitations (5,9).…”
Section: Introductionmentioning
confidence: 99%