2004
DOI: 10.1117/12.542705
|View full text |Cite
|
Sign up to set email alerts
|

Whole-body 35-GHz security scanner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2005
2005
2011
2011

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…The current mm-wave system is the L-3 Communications ProVision (http://www.sds.l-3com.com/advancedimaging/provision-at.htm), and the backscatter system is the Rapiscan Secure 1000 (http://www.rapiscansystems.com/sec1000.html). Active and passive millimeter-wave imaging systems have been demonstrated to detect a wide variety of concealed threats including explosives, handguns, and knives [1][2][3][4] . The cylindrical millimeter-wave imaging technology was developed at the Pacific Northwest National Laboratory (PNNL) and has been licensed to L-3 Communications (originally SafeView) [5][6][7][8] .…”
Section: Introductionmentioning
confidence: 99%
“…The current mm-wave system is the L-3 Communications ProVision (http://www.sds.l-3com.com/advancedimaging/provision-at.htm), and the backscatter system is the Rapiscan Secure 1000 (http://www.rapiscansystems.com/sec1000.html). Active and passive millimeter-wave imaging systems have been demonstrated to detect a wide variety of concealed threats including explosives, handguns, and knives [1][2][3][4] . The cylindrical millimeter-wave imaging technology was developed at the Pacific Northwest National Laboratory (PNNL) and has been licensed to L-3 Communications (originally SafeView) [5][6][7][8] .…”
Section: Introductionmentioning
confidence: 99%
“…or passive sources emitting blackbody radiation by virtue of a temperature differential. A number of methods have been proposed and described in the literature including active arrays based on wideband oscillators [2] and tuned cavities [3]. A major drawback of using these active methods is the potential for image artifact in the form of speckle, glint and ringing.…”
Section: Indoor Imagingmentioning
confidence: 99%
“…The main performances of MMW imaging system are the field of view, the spatial resolution and the thermal sensitivity, and the field of view and spatial resolution are researched by quasi-optical subsystem [1]. Best spatial resolution and enough field of view can be obtained by reasonable design of quasioptics in order to improve the performances of detecting contrabands.…”
Section: Introductionmentioning
confidence: 99%