2021
DOI: 10.15761/jts.1000465
|View full text |Cite
|
Sign up to set email alerts
|

White light spectroscopy for T-cell culture growth monitoring: towards a real-time and sampling free device for ATMPs production

Abstract: Nowadays, Advanced Therapy Medicinal Products (ATMPs) are new generation of pharmaceuticals which offer novel and revolutionary answer to be given to patients at the end of their therapeutic options. However, because of their prohibitive cost, they can only be proposed to a reduced number of patients. One possibility to reduce ATMP' price is to automate their production as much as possible. Among the numerous possibilities, a real-time and closed loop monitoring of the T-cell growth during the expansion phase … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
17
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(18 citation statements)
references
References 18 publications
1
17
0
Order By: Relevance
“…In the Beer–Lambert derived model [ 30 ], the value of the maxima of each spectrum was used to compute the corresponding concentration, but this model cannot be used to simultaneously compute concentrations of species within a mixture. Here, the information contained in the whole absorption spectrum was exploited to establish a model describing the evolution of CEM absorption spectra with the concentration.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…In the Beer–Lambert derived model [ 30 ], the value of the maxima of each spectrum was used to compute the corresponding concentration, but this model cannot be used to simultaneously compute concentrations of species within a mixture. Here, the information contained in the whole absorption spectrum was exploited to establish a model describing the evolution of CEM absorption spectra with the concentration.…”
Section: Resultsmentioning
confidence: 99%
“…The spectra shape model calculated an initial CEM concentration of 4.6 × 10 5 cells.mL −1 while the cuvette was initially filled with a concentration of 5 × 10 5 cells.mL −1 . This value was correct, especially considering that the cell counter measurements were not fully representative of the real concentration within the culture flask (see Discussion and [ 30 ]).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations