2019
DOI: 10.1186/s13054-019-2413-x
|View full text |Cite
|
Sign up to set email alerts
|

What is the lowest change in cardiac output that transthoracic echocardiography can detect?

Abstract: Background In critically ill patients, changes in the velocity-time integral (VTI) of the left ventricular outflow tract, measured by transthoracic echocardiography (TTE), are often used to non-invasively assess the response to fluid administration or for performing tests assessing fluid responsiveness. However, the precision of TTE measurements has not yet been investigated in such patients. First, we aimed at assessing how many measurements should be averaged within one TTE examination to reach … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
74
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 87 publications
(76 citation statements)
references
References 34 publications
2
74
0
Order By: Relevance
“…Regarding this point, the reported intra-and interobserver variabilities are low among studies (ranging between 3 and 8%) [16,24,29,38]. In a recent study, the lowest smallest change for the LVOT VTI (i.e., the smallest change that can be considered as significant and not related to the imprecision of the method or the variability of the parameter) was found to be < 5% for intra-examinations (i.e., without removing the probe from the chest wall), while it averages 11% for inter-examinations (i.e., removing the probe from the chest wall) [37].…”
Section: Feasibility and Reliability For The Vti In Point-of-care Setmentioning
confidence: 93%
See 1 more Smart Citation
“…Regarding this point, the reported intra-and interobserver variabilities are low among studies (ranging between 3 and 8%) [16,24,29,38]. In a recent study, the lowest smallest change for the LVOT VTI (i.e., the smallest change that can be considered as significant and not related to the imprecision of the method or the variability of the parameter) was found to be < 5% for intra-examinations (i.e., without removing the probe from the chest wall), while it averages 11% for inter-examinations (i.e., removing the probe from the chest wall) [37].…”
Section: Feasibility and Reliability For The Vti In Point-of-care Setmentioning
confidence: 93%
“…In these cases, it is recommended to average at least five VTIs in order to obtain a more accurate VTI value (Fig. 8) [23,37].…”
Section: Limitations Of the Lvot Vtimentioning
confidence: 99%
“…SVV in patients with mechanical ventilation is less than 10-15%. According to cardiopulmonary interaction under mechanical ventilation and Frank-Starling principle, a change in stroke volume caused by mechanical ventilation is more significant when the blood volume is insufficient, showing a negative correlation between SVV and the blood volume [ 16 , 17 ]. Theoretically, SVV can therefore be used to estimate the intravascular volume state and predict the responsiveness of the circulatory system to the infusion treatment.…”
Section: Discussionmentioning
confidence: 99%
“…showing a negative correlation between SVV and the blood volume. (16,17) Theoretically, SVV can therefore be used to estimate the intravascular volume state and predict the responsiveness of the circulatory system to the infusion treatment.…”
Section: Discussionmentioning
confidence: 99%