2021
DOI: 10.3390/en14040972
|View full text |Cite
|
Sign up to set email alerts
|

What Is the Effect of Outer Jacket Degradation on the Communication Parameters? A Case Study of the Twisted Pair Cable Applied in the Railway Industry

Abstract: Among the variety of problems encountered in transmission lines, the outer jacket degradation-derived faults of communication cables in railway applications have a significant impact on the transmission line parameters, especially if the cables are exposed to extremely varying environmental conditions, such as temperature deviation and humidity changes. In this paper, an advanced model of a twisted pair communication cable is proposed, together with approximated degradation functions for distributed parameters… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(13 citation statements)
references
References 22 publications
0
9
0
Order By: Relevance
“…Nowadays, serial communication interfaces (e.g., CAN [16]) become widely used in the railway industry, because of the cost efficiency and acceptable transfer rate-a cable of minimum length can be used for connecting of all the devices in bus topology over extensive areas. A general diagram of the wheel detector communication lines topology is shown in Figure 1 [15]. A CPU (i.e., an evaluator) is usually located in a relay room, but wheel detectors (remote units) are mounted on the rails in a distributed manner over long distances.…”
Section: Problem Descriptionmentioning
confidence: 99%
See 3 more Smart Citations
“…Nowadays, serial communication interfaces (e.g., CAN [16]) become widely used in the railway industry, because of the cost efficiency and acceptable transfer rate-a cable of minimum length can be used for connecting of all the devices in bus topology over extensive areas. A general diagram of the wheel detector communication lines topology is shown in Figure 1 [15]. A CPU (i.e., an evaluator) is usually located in a relay room, but wheel detectors (remote units) are mounted on the rails in a distributed manner over long distances.…”
Section: Problem Descriptionmentioning
confidence: 99%
“…A typical protection circuit scheme is presented in Figure 3 . It is excited by the surge generator [ 25 ] and a wayside transmission cable model described in [ 15 ]. The presented surge generator was verified during preliminary tests.…”
Section: Protection Circuit Topology and Its Parameter Domainmentioning
confidence: 99%
See 2 more Smart Citations
“…In contrast to this work, we investigate underground cables which have a separate set of challenges such as being prone to contamination of foreign materials, corrosion due to water clogs. [21] investigates the outer insulation degradation in shielded twisted pair railway cables and its impact on communication parameters. Our testbeds demonstrate a non-invasive online fault detection and location.…”
Section: Introductionmentioning
confidence: 99%