Wearable Modular Telemetry System for the Integrated Rescue System Operational Use

Abstract: The article summarizes the development of the FlexiGuard modular telemetry system designed for enhancing safety of the Integrated Rescue System team members in solving crisis situations and for improving training processes. Further framework solutions, which lead to the development of automatic modular telemetry system allowing for real time monitoring of physiological parameters, are provided as well. The system provides for the signalization of critical states such as exhaustion, mental stress, and overheati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…For this reason, it was not possible to use Oxycon Mobile (JAEGER ® Oxycon Mobile, Hoechberg, Germany), which we used in laboratories to determine energy expenditure. Instead, we used the FlexiGuard system [17,22] also developed at our institute.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For this reason, it was not possible to use Oxycon Mobile (JAEGER ® Oxycon Mobile, Hoechberg, Germany), which we used in laboratories to determine energy expenditure. Instead, we used the FlexiGuard system [17,22] also developed at our institute.…”
Section: Discussionmentioning
confidence: 99%
“…These nodes were not used during this study. More detailed information about the system is given elsewhere [17]. Using the FlexiGuard device is entirely safe.…”
Section: Introductionmentioning
confidence: 99%
“…Heart activity measurements were performed by means of FlexiGuard (Czech Technical University in Prague, Prague, Czech Republic) mobile telemetry system [29,30] dedicated to physiological parameters recording. The main monitored parameter was heart activity, so the data collection was based on recording RR intervals (time intervals between R peaks of QRS complex when measuring electrocardiogram) [31].…”
Section: Data Collection and Pre-processingmentioning
confidence: 99%
“…It means that by measuring pilot's load we are able to quantify pilot performance (for particular results, see [8,9]). For this purpose, the research project made use of measurement equipment of the Faculty of Biomedicine Engineering, CTU in Prague [10,11].…”
Section: Measuring Pilot Performance By Way Of Definingmentioning
confidence: 99%