Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners

Abstract: BackgroundThe low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking.Questions/purposesWe asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
39
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(44 citation statements)
references
References 41 publications
(50 reference statements)
4
39
0
1
Order By: Relevance
“…Conventional UHMWPE cups were implanted in all THAs included in this study. Modern crosslinked polyethylenes exhibit considerably lower wear related to contact stress [36] and other factors like thirdbody wear [5] might be more important for its wear in vivo. Sixth, current contact stress modeling is based on the assumption of elastic deformation of polyethylene.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Conventional UHMWPE cups were implanted in all THAs included in this study. Modern crosslinked polyethylenes exhibit considerably lower wear related to contact stress [36] and other factors like thirdbody wear [5] might be more important for its wear in vivo. Sixth, current contact stress modeling is based on the assumption of elastic deformation of polyethylene.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, cemented acetabular cups were included in the analysis. it is not likely to change the contact mechanics because no difference in wear between a cemented and an uncemented cup was found in a clinical study [33] and in hip simulator testing [36]. All implanted prostheses have the same femoral head diameter and polyethylene liners with a thickness of 6 mm or greater.…”
Section: Discussionmentioning
confidence: 99%
“…However, in order to use larger femoral heads with a constant cup size, the liner thickness has to be reduced, which leads to higher stresses in the polyethylene [10]. The reduced mechanical properties of HX-PE [11,12] should be critically examined, especially with regard to low thickness of the liner.…”
mentioning
confidence: 99%
“…The linear restraint system is characterized and discussed afterwards (see Table 4 and discussion). [64][65][66][67] wear testing of established artificial joints like the hip or the knee. Therefore, a comparably relevant wear volume is also generated for TAR.…”
Section: Clinical Relevancementioning
confidence: 99%