2001
DOI: 10.1016/s0142-9612(00)00306-9
|View full text |Cite
|
Sign up to set email alerts
|

Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
85
0

Year Published

2001
2001
2019
2019

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 146 publications
(90 citation statements)
references
References 20 publications
3
85
0
Order By: Relevance
“…A number of papers do not state the type of DLC used [4,[40][41][42][43][46][47][48], while those that do state they are using ta-C or a-C:H, they fail to mention the composition ratio. While the manufacturing method and the source material enable an estimation of the composition, without knowing the exact conditions during the deposition, it remains little more than a guess.…”
Section: Potential Reasons For Differing Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…A number of papers do not state the type of DLC used [4,[40][41][42][43][46][47][48], while those that do state they are using ta-C or a-C:H, they fail to mention the composition ratio. While the manufacturing method and the source material enable an estimation of the composition, without knowing the exact conditions during the deposition, it remains little more than a guess.…”
Section: Potential Reasons For Differing Resultsmentioning
confidence: 99%
“…Finally the thickness of interlayers and coatings are also often excluded, which again play a significant role in the coatings performance. Saikko et al [43] noted that different serums can cause different results, due to the different types of biological interactions that occur and the severity of these interactions in the fluid. In addition to this, some serum tests use additives like EDTA to prevent the serum clotting, this can change the chemistry of the serum and the interactions of the proteins on the surface, affecting the overall performance.…”
Section: Potential Reasons For Differing Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…It concerns a total hip prosthesis wear. To deal with this type of problem some authors have adopted an experimental basis using hip simulators [7], [24], [2]. This type of approach allows quite accurate estimation of wear loss and location.…”
Section: Numerical Simulations : Total Hip Prosthesismentioning
confidence: 99%