2017
DOI: 10.1007/s10856-017-5879-6
|View full text |Cite
|
Sign up to set email alerts
|

Wear of Morse taper and external hexagon implant joints after abutment removal

Abstract: The aim of this in vitro study was to evaluate the removal torque values on abutments and the morphological wear aspects of two different dental implant joints after immersion in a medium containing biofilm from human saliva. Twenty implant-abutment assemblies were divided into four groups in this study: (A) Morse taper free of medium containing biofilm, and (B) after contact with a medium containing biofilm from human saliva; (C) External Hexagon free of medium containing biofilm, and (D) after contact with m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 23 publications
0
13
0
1
Order By: Relevance
“…This result contradicts previous studies that have demonstrated the effectiveness of this connection in the containment of the microbial infiltration to its interface. [14, 30, 34]…”
Section: Discussionmentioning
confidence: 99%
“…This result contradicts previous studies that have demonstrated the effectiveness of this connection in the containment of the microbial infiltration to its interface. [14, 30, 34]…”
Section: Discussionmentioning
confidence: 99%
“…The high density of biofilm biomass could protect bacteria or spores located at retentive micro‐regions of the abutments leading to a potential re‐growth in nutrient‐rich medium such as found in the oral cavity. Retentive micro‐regions are inherent on healing abutments as a result of the machining process, surface treatment, and desiging 33,34 . Defects found on abutments and implant joint surfaces can promote a misfit between the implant and abutment connection 10,18,33,34 .…”
Section: Resultsmentioning
confidence: 99%
“…Retentive micro‐regions are inherent on healing abutments as a result of the machining process, surface treatment, and desiging 33,34 . Defects found on abutments and implant joint surfaces can promote a misfit between the implant and abutment connection 10,18,33,34 . As a consequence of the implant‐abutment misfit, the size of microgaps between abutment and implant can vary from 0.1 up to 15 μm 10,18,33 .…”
Section: Resultsmentioning
confidence: 99%
“…В организме происходит постепенное разруше ние, изнашивание всех инородных тел, даже кон струкций из очень прочных искусственных матери алов при контакте с биологическими тканями и жидкостями [2, 3], в том числе и имплантатов, из готовленных на основе титана [4,5,14,15].…”
Section: особенности реакций живых тканей на дентальную имплантациюunclassified