2002
DOI: 10.1002/jbm.10471
|View full text |Cite
|
Sign up to set email alerts
|

Wear of conventional and cross‐linked ultra‐high‐molecular‐weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator

Abstract: The wear of acetabular cups made from conventional gamma-sterilized, and electron-beam cross-linked ultra-high-molecular-weight polyethylene was studied with a biaxial hip wear simulator. The femoral heads were either polished or roughened so that they represented the type of roughening and the value of surface roughness (R(a) = 0.14-0.18 micro m) observed in the roughest explanted femoral heads. The lubricant was diluted calf serum, and the test length 3 million cycles. The mean wear rate and standard deviati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
55
1

Year Published

2003
2003
2015
2015

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 78 publications
(61 citation statements)
references
References 13 publications
(40 reference statements)
5
55
1
Order By: Relevance
“…A 50 mm diameter Metasul MoM joint was first run in water, then dry and finally in serum. The crosslinked polyethylene cup (Durasul) was described in an earlier study [17]. It was run against smooth and roughened (Ra 0.1 µm) CoCr (MoP) and alumina (AoP) heads of 28 mm diameter, lubricated and dry.…”
Section: Methodsmentioning
confidence: 99%
“…A 50 mm diameter Metasul MoM joint was first run in water, then dry and finally in serum. The crosslinked polyethylene cup (Durasul) was described in an earlier study [17]. It was run against smooth and roughened (Ra 0.1 µm) CoCr (MoP) and alumina (AoP) heads of 28 mm diameter, lubricated and dry.…”
Section: Methodsmentioning
confidence: 99%
“…These PEs were included because the effect of crosslinking on the size and morphology of the particles was examined in several prior studies with varying results [1,4,12,41,42]. Two types of crosslinked PE were included to demonstrate the ability of the protocol to detect subtle differences between the two materials.…”
Section: Methodsmentioning
confidence: 99%
“…In vitro studies have shown that these materials show great improvements in resistance to wear [13,16,20]. Nevertheless, hip simulator data is not always consistent with clinical findings [10,14].…”
Section: Introductionmentioning
confidence: 99%