1995
DOI: 10.1016/0043-1648(95)90030-6
|View full text |Cite
|
Sign up to set email alerts
|

Wear mechanisms of UHMWPE in total joint replacements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
49
0

Year Published

1999
1999
2013
2013

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 106 publications
(52 citation statements)
references
References 22 publications
3
49
0
Order By: Relevance
“…Some laboratories use undiluted bovine serum while others use dilute the bovine serum by adding deionized water. Wear rate of conventional polyethylene has been shown to increase with dilution of bovine serum [28]. However, at extreme dilutions, non-physiological wear mechanisms have been shown to dominate the wear process [29].…”
Section: Discussionmentioning
confidence: 99%
“…Some laboratories use undiluted bovine serum while others use dilute the bovine serum by adding deionized water. Wear rate of conventional polyethylene has been shown to increase with dilution of bovine serum [28]. However, at extreme dilutions, non-physiological wear mechanisms have been shown to dominate the wear process [29].…”
Section: Discussionmentioning
confidence: 99%
“…As far as the correlation between scratching of femoral heads and the wear of UHMWPE components is concerned, discrepancies have been observed between the quantitative results of different laboratory wear tests and clinical observations [2,3,[6][7][8][9]. These discrepancies have mainly been attributed to the fact that, in clinical situations, localized head scratching may occur and generate damaged regions whose sites, size and severity magnitude are seemingly randomly distributed [2,3,7,10].…”
Section: Introductionmentioning
confidence: 91%
“…Despite the growing success of this type of surgery, limiting the wear of UHMWPE components remains a key issue to improve the long-term performance of these Charnley type prostheses. While the influence of variations in component design, in surgical technique and/or in patient activity level cannot be ignored, the scratching of the metallic femoral head is currently thought to be a major factor affecting the wear rate of the UHMWPE counterface [1][2][3][4][5][6][7][8][9][10]. This scratching phenomenon is increasingly suspected to be caused by hard third bodies such as particles of bone, cement and/or metal, which have often been found embedded in acetabular cups and in the peri-prosthetic tissues [1][2][3][4][5]11,12].…”
Section: Introductionmentioning
confidence: 99%
“…At the same time, obvious traces of wearing through fretting of the acetabular cup of UHMWPE. In some studies this traces are confounded or assimilated with the adhesive wear [5][6]. Starting with the well-known fact that the rolling movement always has a lower friction compared to sliding friction, the authors have conceived and realized a pivoting movement joint on a "layer of balls" with "compensation space", placed between the acetabular cup and the femoral head.…”
Section: Mom Hip Prosthesis With Self Directed Rolling Ballsmentioning
confidence: 99%