Abstract: Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligame… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 42 publications
1
6
0
1
Order By: Relevance
“…Weaker quadriceps would have presumably less passive stiffness [32] which, due to the patellar tendon's anatomical function as part of the quadriceps muscle-tendon unit [33,34], would most likely increase buckling within the patellar tendon. A potential effect of such extreme buckling is joint instability, which can lead to abnormal knee joint loading and increased degenerative wear [35]. Pre-operative differences in patellar tracking could also be relevant to consider.…”
Section: Discussionmentioning
confidence: 99%
“…Weaker quadriceps would have presumably less passive stiffness [32] which, due to the patellar tendon's anatomical function as part of the quadriceps muscle-tendon unit [33,34], would most likely increase buckling within the patellar tendon. A potential effect of such extreme buckling is joint instability, which can lead to abnormal knee joint loading and increased degenerative wear [35]. Pre-operative differences in patellar tracking could also be relevant to consider.…”
Section: Discussionmentioning
confidence: 99%
“…Po wszech nie wia do mo, iż zbyt "cia sne" ko la no z nad mier ną zwar to ścią wię za deł po bocz nych, mo że być przy czy ną do le gli wo ści bó lo wych i ogra ni cze nia za kre su ru chu [10]. Z dru giej stro ny, nie sta bil ność jest jed ną z naj częst szych przy czyn nie po wo dzeń endo pro te zo pla sty ki sta wu ko la no we go [11]. Nie któ rzy au to rzy do wo dzą, iż pe wien sto pień "lu zu" w sta wie jest nie zbęd ny i przy czy nia się do zmniej sze nia odczu wa nia bó lu po ope ra cyj ne go, a ta kże umo żli wia więk szy za kres ru chu [12,13].…”
Section: Wstępunclassified
“…It is well known that too tight collateral ligaments may result in knee pain and ROM limitations [10]. On the other hand, instability is one of the main causes of implant failure [11]. However, some investigators argue that a certain degree of laxity in the joint may be related to decreased postoperative pain and a better range of motion [12;13].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the relative sliding of components and higher compressive load can lead to greater implant wear. More conforming implant designs that provide greater knee stabilization have been shown to have significantly lower wear rates (Brockett et al, 2017;Reinders et al, 2014).…”
Section: Muscle Activation Strategies In the Unstable Kneementioning
confidence: 99%
“…However, muscular co-contraction can be mechanically inefficient and can hinder joint functionality. Furthermore, the relative sliding of components and higher compressive load can lead to greater implant wear (Brockett et al, 2017;Reinders et al, 2014). TKR patients present with slowed gait, reduced range of motion and prolonged muscular co-contractions during stance (Benedetti et al, 2003).…”
Section: Motivationmentioning
confidence: 99%