2011 International Conference on Computer, Communication and Electrical Technology (ICCCET) 2011
DOI: 10.1109/icccet.2011.5762486
|View full text |Cite
|
Sign up to set email alerts
|

Wavelet based pulse rate and Blood pressure estimation system from ECG and PPG signals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…Regarding the research on BP estimation, most studies use a combination of electrocardiogram (ECG) and photoplethysmogram (PPG) sensors [ 16 , 17 , 18 ], making the problem even more complex and equipment necessary. The common techniques used for obtaining measurements on BP mainly rely on Pulse Wave Velocity (PWV), Pulse Arrival Time (PAT), and Pulse Transit Time (PTT) [ 19 , 20 , 21 , 22 ], all of which require an accurate PPG measurement, which is not simple to get unobtrusively yet, and no clear proof on the PPG measurement’s relation to the BP has been provided [ 23 , 24 , 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…Regarding the research on BP estimation, most studies use a combination of electrocardiogram (ECG) and photoplethysmogram (PPG) sensors [ 16 , 17 , 18 ], making the problem even more complex and equipment necessary. The common techniques used for obtaining measurements on BP mainly rely on Pulse Wave Velocity (PWV), Pulse Arrival Time (PAT), and Pulse Transit Time (PTT) [ 19 , 20 , 21 , 22 ], all of which require an accurate PPG measurement, which is not simple to get unobtrusively yet, and no clear proof on the PPG measurement’s relation to the BP has been provided [ 23 , 24 , 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…However valuable information about cardiovascular vital parameters can be extracted from frequency-domain and time-frequency features of PPG [55][56][57][58]. FMD-induced changes in these features may help in a better evaluation of the endothelial function.…”
Section: Future Directionsmentioning
confidence: 99%
“…However, many conventional cuffless PTT-based BP estimation studies have some drawbacks, divided into four categories: (1) analysis of biased, (2) small datasets, (3) studies with devices that required calibration, and (4) insufficient accuracy as required by international standards. Some studies analyzed biased data that included only young participants with a narrow blood pressure range (12,13), while others had insufficient participants (13)(14)(15)(16)(17)(18). Other studies needed additional advanced preparations such as frequent calibrations (19)(20)(21), required additional parameters (22,23), or used devices that needed to be anchored to the body, resulting in annoyance for some users (24).…”
Section: Introductionmentioning
confidence: 99%