2016
DOI: 10.1016/j.sna.2016.02.016
|View full text |Cite
|
Sign up to set email alerts
|

Wavelength-meter controlled cavity ring-down spectroscopy: high-sensitivity detection of trace moisture in N 2 at sub-ppb levels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 39 publications
0
18
0
Order By: Relevance
“…When these two capacitors are connected in parallel, the sensitivity is enhanced almost two-fold but the actual size remains unchanged. Also, this structure prevents the wastage of very useful dip-coated film on the opposite side of the substrate as reported previously in [7,9,14,16,17,[21][22][23]. The proposed method of sensitivity enhancement is easy, simple, and less time consuming.…”
Section: Introductionmentioning
confidence: 83%
See 3 more Smart Citations
“…When these two capacitors are connected in parallel, the sensitivity is enhanced almost two-fold but the actual size remains unchanged. Also, this structure prevents the wastage of very useful dip-coated film on the opposite side of the substrate as reported previously in [7,9,14,16,17,[21][22][23]. The proposed method of sensitivity enhancement is easy, simple, and less time consuming.…”
Section: Introductionmentioning
confidence: 83%
“…Additionally, the size of the device remains unchanged and the costly sensing film which is deposited on the opposite side can be effectively utilized. This is because, when thin film is deposited on the gold-plated electrode by the dip coating method, the film deposited on the opposite side of the alumina substrate remains unused [8,[12][13][14][15][16][17][18][19][20][21][22]. This issue has not been addressed by previous reported work.…”
Section: Sensitivity Enhancement By Connecting Two Capacitors In Paramentioning
confidence: 99%
See 2 more Smart Citations
“…Trace water in industrial gases must be monitored at many points during such processes to avoid undesirable loss of materials and energy. Appropriate detection methods for trace water in industrial gases are limited to cavity ring-down spectrometers (CRDS), 3,4 chilled-mirror hygrometers, 5 capacitive sensors, 6,7 and pulsed discharge helium ionization detector following chromatographic separation. 8 These methods are not perfect for this purpose in terms of a sensitivity, a response time, and an economy.…”
Section: Introductionmentioning
confidence: 99%