Water-Related Nosocomial Pneumonia Caused by Legionella pneumophila Serogroups 1 and 10

Abstract: Between August 1978 and November 1983, 21 cases of pneumonia caused by Legionella pneumophila occurred in the Leiden University Hospital, mainly among immunocompromised patients. A new serogroup of L. pneumophila, designated serogroup 10 (prototype strain Leiden 1), was isolated from bronchial secretions of four patients, and five patients had serological evidence of infection with this organism. Nine patients had a culture-confirmed infection with L. pneumophila serogroup 1. L. pneumophila serogroups 1 and 10… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
39
1
1

Year Published

1987
1987
2022
2022

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 94 publications
(42 citation statements)
references
References 25 publications
1
39
1
1
Order By: Relevance
“…Our findings indicate that the hospital water has to be considered the source of nosocomial legionella infections. This is consistent with those of other studies (Meenhorst et al 1985;Neill et al 1985). There is no evidence that other potential sources were implicated.…”
Section: Discussionsupporting
confidence: 94%
See 1 more Smart Citation
“…Our findings indicate that the hospital water has to be considered the source of nosocomial legionella infections. This is consistent with those of other studies (Meenhorst et al 1985;Neill et al 1985). There is no evidence that other potential sources were implicated.…”
Section: Discussionsupporting
confidence: 94%
“…A number of techniques, e.g. plasmid analysis, subtyping with monoclonal antibodies (MAB), have been used to prove the identity of corresponding clinical and environmental legionella 648 B. RUF AND OTHERS isolates, and thus to localize the likely source of infection (Edelstein et al 1986b;Meenhorst et al 1985;Neil et al 1985). In the Rudolf Virchow University Hospital (UKRV) legionellae were also found to be a cause of nosocomial pneumonia.…”
Section: Introductionmentioning
confidence: 99%
“…These samples correspond to cold domestic waters or well deep waters known to be free of Legionella. Eight samples analyzed in singular (samples 1,3,10,11,19,36,37) or in duplicates (sample 23) were positive by the IDS method but negative in culture, whereas the opposite was never found. It is interesting that the sampling temperature of these water samples (excepting samples 1 and 37) exceeded 45°C.…”
Section: Resultsmentioning
confidence: 95%
“…appear to represent a health risk to humans when a threshold value estimated at 10 4 to 10 5 CFU liter Ϫ1 is reached. Epidemiological data show that outbreaks of legionellosis occur at these concentrations (37,44), and corrective actions such as chlorination must be taken promptly in the case of contaminations. Besides a monitoring of water quality, the IDS method described in this study also allows the evaluation of the efficiency of the disinfection measures as suggested by the chlorination results.…”
Section: Discussionmentioning
confidence: 99%
“…Regrowth is limited by a far-reaching removal of growth-promoting compounds from the water to achieve biological stability (57). A number of reports showed that L. pneumophila multiplying in hot-water systems in buildings originated from the water supply (27,27,37). The aim of our study was to elucidate the role of drinking water in the distribution of Legionella.…”
mentioning
confidence: 97%