2019
DOI: 10.3390/pathogens8040295
|View full text |Cite
|
Sign up to set email alerts
|

Water Quality as a Predictor of Legionella Positivity of Building Water Systems

Abstract: Testing drinking water systems for the presence of Legionella colonization is a proactive approach to assess and reduce the risk of Legionnaires’ disease. Previous studies suggest that there may be a link between Legionella positivity in the hot water return line or certain water quality parameters (temperature, free chlorine residual, etc.) with distal site Legionella positivity. It has been suggested that these measurements could be used as a surrogate for testing for Legionella in building water systems. We… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 32 publications
(29 citation statements)
references
References 28 publications
1
25
1
Order By: Relevance
“…However, these correlations were location and sample type specific with conflicting positive and negative correlations for turbidity and HPC. Conflicting correlations between the latter and Legionella levels have been reported previously with either strong correlations [81], no correlations [82][83][84][85], or possible seasonal dependencies for these correlations [7]. Other conflicting correlations were reported between Legionella occurrence and pH, temperature, various minerals and metals (Ca, Cu, Fe, Mg, Mn, and Zn), total organic carbon, conductivity, and free chlorine at the sampling site and building supply feed [85][86][87].…”
Section: Discussionmentioning
confidence: 99%
“…However, these correlations were location and sample type specific with conflicting positive and negative correlations for turbidity and HPC. Conflicting correlations between the latter and Legionella levels have been reported previously with either strong correlations [81], no correlations [82][83][84][85], or possible seasonal dependencies for these correlations [7]. Other conflicting correlations were reported between Legionella occurrence and pH, temperature, various minerals and metals (Ca, Cu, Fe, Mg, Mn, and Zn), total organic carbon, conductivity, and free chlorine at the sampling site and building supply feed [85][86][87].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, recently no significant correlation between distal site Legionella positivity and hot water return line temperature has been found. In particular, also buildings with a hot water return temperature >51.1 °C have been found positive for the bacterium in distal sites [ 14 ]. These findings imply not only that temperature should not be used alone to predict the presence or absence of Legionella in a drinking water distribution system, but also that it is crucial to evaluate the effectiveness of the applied thermal water management program.…”
Section: Factors Related To the Growth And Survival Of Legionellaementioning
confidence: 99%
“…In general, an impact of magnesium on Legionella abundance has not yet been demonstrated so far. There were large-scale investigations in residential drinking water distribution systems (DWDS) that included magnesium in the overall analysis of environmental drivers for Legionella abundance [35,36]. However, due to low magnesium concentrations in these DWDS (<3 mg/L), an effect of magnesium was not observed.…”
Section: Influence Of Physico-chemical and Bacteriological Factors On Legionella Abundancementioning
confidence: 99%