2010
DOI: 10.1088/1742-6596/250/1/012093
|View full text |Cite
|
Sign up to set email alerts
|

Water equivalency evaluation of PRESAGE®dosimeters for dosimetry of Cs-137 and Ir-192 brachytherapy sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 10 publications
1
11
0
Order By: Relevance
“…8 This system has been used extensively for external beam radiotherapy 1,2 and in a few cases, to measure the dose distribution about a brachytherapy source. 10,11 Verification of the attenuation characteristics of brachytherapy applicators is a natural extension of previously reported applications of the PRESAGE/DLOS 3D dosimetry system.…”
Section: Introductionmentioning
confidence: 90%
See 1 more Smart Citation
“…8 This system has been used extensively for external beam radiotherapy 1,2 and in a few cases, to measure the dose distribution about a brachytherapy source. 10,11 Verification of the attenuation characteristics of brachytherapy applicators is a natural extension of previously reported applications of the PRESAGE/DLOS 3D dosimetry system.…”
Section: Introductionmentioning
confidence: 90%
“…10,26 In addition to this, we evaluated the PRESAGE/DLOS system for measurements of 137 Cs by first measuring the 3D dose distribution about an unshielded source, after which the distribution was measured about sources placed within the attenuating buckets. Cylindrical polymer based PRESAGE dosimeters 1,2,21 (9.5 cm diameter, 9.2 cm height) were manufactured.…”
Section: Iib2 3d Dosimetrymentioning
confidence: 99%
“…15,16 These attributes are especially important for brachytherapy measurements with high dose gradients and requiring source placement within the dosimeter via a channel. 17 PRESAGE R has already been applied to measure the dose distribution surrounding cesium-137 and iridium-192 brachytherapy sources [18][19][20] in conjunction with the Duke Large field of view optical CT-scanner (DLOS). 17,21 Recent advances in 3D dosimetry technology have potential to make feasible dose measurements surrounding low energy sources as well.…”
Section: Presagementioning
confidence: 99%
“…25 Water equivalence of some formulations has been evaluated for various photon and particle beam energies, 18,26 but has yet to be quantified for low energy brachytherapy sources. 2.…”
Section: Water Equivalency Of Polyurethane Dosimeters For Lowmentioning
confidence: 99%
“…The radiological properties including effective atomic number, number of electrons per gram, mass density and electron density should be same as radiological properties of water or tissue [7,8]. Several studies have been done to investigate water equivalency of different polymer gel dosimetry for photon and electron beam dosimetry [1,[9][10][11][12][13][14][15][16][17][18]. MAGIC gel dosimeter has previously been investigated for its radiological interaction properties and radiological water equivalence [1,10].…”
Section: Introductionmentioning
confidence: 99%