1992
DOI: 10.1021/j100200a028
|View full text |Cite
|
Sign up to set email alerts
|

Wall-jet electrode linear sweep voltammetry

Abstract: 8363(10) Samdal, S.; Seip, H. M.; Torgrimsen, T. J. Mol. S t r u t . Theory is presented which predicts the linear sweep voltammetry behavior at the wall-jet electrode for a reversible couple. The scan rate and electrode geometry dependences are established, and hence the requirements for the measurement of true "steady state" hydrodynamic voltammograms are defmed. Theory is found to be in good agreement with experiments conducted on the oxidation of the ferrocyanide anion in aqueous solution.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
15
0

Year Published

1995
1995
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 8 publications
1
15
0
Order By: Relevance
“…The fluid cell was designed to produce a vertically impinging fluid jet onto the sample surface within 2 mm of the AFM probe contact. This ''wall-jet'' (Compton et al, 1992) flow configuration produced an effective residence time at the tip-sample contact of approximately 60 ms, which aided the study of transient processes.…”
Section: Methodsmentioning
confidence: 99%
“…The fluid cell was designed to produce a vertically impinging fluid jet onto the sample surface within 2 mm of the AFM probe contact. This ''wall-jet'' (Compton et al, 1992) flow configuration produced an effective residence time at the tip-sample contact of approximately 60 ms, which aided the study of transient processes.…”
Section: Methodsmentioning
confidence: 99%
“…19, 20 In this work, the optimized 3D-printed WJE device was compared with a 3D-printed TLE device. To ensure an accurate comparison, the TLE channel size is the same as the WJE outlet channel size where the electrode is housed (750 μm × 750 μm).…”
Section: Resultsmentioning
confidence: 99%
“…A wall jet electrode (WJE) is an alternative electrode configuration that has been reported for tubing-based systems. 1820 A WJE design (Figure 2A) allows the sample to hit the electrode embedded at the end the sample inlet channel, perpendicular to the inlet flow stream, which has proven to enhance mass transport and thus increase sensitivity. Although there are a few reports showing the integration of WJE in microfluidic devices, they used glass microchannels (requiring clean room for fabrication) and the electrode has to be manually aligned with the separation channel since the electrode is separate from the microchip.…”
Section: Introductionmentioning
confidence: 99%
“…Computational procedures have also been employed [16] to deduce these parameters; the exploitation of the highly non-uniform accessibility for better discrimination between electrode reaction mechanisms than at uniformly accessible electrodes has been demonstrated [17]. Potential-step chronoamperometry [18,19] and linear sweep voltammetry [20] have also been investigated and the limitations of using approximate theoretical responses examined.…”
mentioning
confidence: 99%
“…In principle, kinetic and mechanistic information can also be obtained and the response analyzed according to the criteria described in Refs. [14][15][16][17][18][19][20]. The following section will discuss how cells should be designed to ensure that wall-jet hydrodynamics can be achieved and the various detection strategies which can be employed.…”
mentioning
confidence: 99%