Abstract: In general, improvements in implant design during the past decade have increased the level of protection of health and safety of hip and knee joint replacement devices. Nevertheless, our data suggest that there is still a certain amount of design problems contributing to implant failure. By increasing the number of reports, users could help to enhance the safety of these devices.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
2
0
2

Year Published

2008
2008
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 17 publications
0
2
0
2
Order By: Relevance
“…Cases of material failure in the form of chipping or breakage are very rare. The failure rates of ceramic ball heads in ceramic self-pairing designs are reported between 0.004 % and 0.06 % [8,9,13,24,27] . Internal statistics of the Mathys Orthopaedie GmbH (Moersdorf/Thuer., Germany) signify failure rates of ceramic ball heads of 0.03 % for head diameter of 28 mm and 0.008 % for head diameter of 32 mm.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…Cases of material failure in the form of chipping or breakage are very rare. The failure rates of ceramic ball heads in ceramic self-pairing designs are reported between 0.004 % and 0.06 % [8,9,13,24,27] . Internal statistics of the Mathys Orthopaedie GmbH (Moersdorf/Thuer., Germany) signify failure rates of ceramic ball heads of 0.03 % for head diameter of 28 mm and 0.008 % for head diameter of 32 mm.…”
Section: Introductionmentioning
confidence: 98%
“…Some reasons for fracture are indicated after fall of the patients, other fractures occur while walking without trauma [8 -10, 12, 15, 17 -19, 20] . It is assumed that many of these failures without trauma could have been prevented with careful intraoperative handling [7,13,26] . Some case reports with ceramic head fracture postulate damaged cones or contaminations within the connection area as reason for breakage [14,18,19] .…”
Section: Introductionmentioning
confidence: 99%
“…"Die gesamte Fallbearbeitung unterliegt aufgrund der gesetzlichen Vorgaben der Vertraulichkeit. Auf die Nennung von Hersteller-oder Produkteigennamen muss daher durchgehend verzichtet werden, es sei denn, es handelt sich um bereits anderweitige oder aus Gründen der Risikoabwehr veröffentlichte und allgemein zugängliche Tatsachen" [19]. Da die ausgewerteten Daten aus einem Spontanerfassungssystem stammen, erfolgt aufgrund der Vielschichtigkeit der Meldungen eine beschreibende statische Auswertung.…”
Section: Introductionunclassified
“…Die Dunkelziffer bei den Meldungen ist groß. So sind beispielsweise für den Zeitraum vom 01.01.2000 bis zum 31.12.2002 insgesamt lediglich 274 Vorkommnismeldungen im Zusammenhang mit Hüft-und Kniegelenkprothesen beim BfArM eingegangen, während die Zahl der im gleichen Zeitraum tatsächlich durchgeführten Wechseleingriffe wesentlich hö-her war[34].Bei den bisher vorliegenden Kohortenstudien zur Ergebnisqualität in der Endoprothetik finden sich verschiedene Verzerrungen (Bias). Ihre Resultate zu Komplikationen weichen teilweise um das mehrfache von den entsprechenden Angaben in bereits bestehenden validen Registern ab[35] und sind daher nicht auf die Grundgesamtheit über-tragbar[35][36][37].…”
unclassified