2014
DOI: 10.2214/ajr.13.12369
|View full text |Cite
|
Sign up to set email alerts
|

Volumetric Analysis of Colonic Distention According to Patient Position at CT Colonography: Diagnostic Value of the Right Lateral Decubitus Series

Abstract: Purpose To compare total colonic gas volume and segmental luminal distention according to patient position at CT colonography (CTC), and determine which two views should constitute the routine protocol. Methods Volumetric analysis was retrospectively performed on CTC examinations from 146 adults (mean age, 59.2 years; 81M/65F; mean BMI, 30.9) where supine, prone, and right lateral decubitus series were sequentially obtained using continuous low-pressure CO2 insufflation. Total colonic gas volumes were assess… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
10
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 21 publications
2
10
0
Order By: Relevance
“…Furthermore, our study underscores the general importance of confirming the mobility or lack of mobility of a suspected lesion on CTC by careful topographic comparisons with other available fixed structures, such as colonic folds, teniae or diverticula, using both, 3-dimensional and 2-dimensional views rather than a simple comparison of apparent lesion locations on 2-dimensional images. This careful interpretive approach is particularly important, since CTC can be obtained not only in the standard supine-prone positions but also in alternative positions, including lateral decubitus positions ( 16 17 18 19 ). The degree and pattern of colonic movement caused by lateral decubitus positions of patients would likely differ from standard supine-to-prone change; hence, comparing lesion locations between different sets of CTC images is even more difficult.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, our study underscores the general importance of confirming the mobility or lack of mobility of a suspected lesion on CTC by careful topographic comparisons with other available fixed structures, such as colonic folds, teniae or diverticula, using both, 3-dimensional and 2-dimensional views rather than a simple comparison of apparent lesion locations on 2-dimensional images. This careful interpretive approach is particularly important, since CTC can be obtained not only in the standard supine-prone positions but also in alternative positions, including lateral decubitus positions ( 16 17 18 19 ). The degree and pattern of colonic movement caused by lateral decubitus positions of patients would likely differ from standard supine-to-prone change; hence, comparing lesion locations between different sets of CTC images is even more difficult.…”
Section: Discussionmentioning
confidence: 99%
“…The total volume and mean attenuation of the residual luminal colonic fluid for each patient were derived using an automated quality assessment (QA) tool available on a beta version of our CTC software system (V3D Colon, Viatronix) that provides the luminal fluid and gas volumes [5, 6, 19]. This portion of the study was conducted by one of the co-authors (B.J.…”
Section: Methodsmentioning
confidence: 99%
“…The parameters Low Threshold, High Threshold and Gaussian sigma (σ) with values in the range 40-50, 100-120 and 1.4 respectively resulted in accurate boundary detection between contrast-colon wall. Then colon blobs are identified using connected component labeling method and finally blobs diameter measuring <2 cm are discarded using knowledge of colon distention grading (Pickhardt et al, 2014). Then the segmented blob region is filled with the original slice voxel intensities so that colon content is absolutely preserved without loss of tissue details.…”
Section: Colon Segmentationmentioning
confidence: 99%