1992
DOI: 10.1002/mrm.1910260203
|View full text |Cite
|
Sign up to set email alerts
|

Volume‐selective proton MRS in vertebral bodies

Abstract: Volume-selective 1H magnetic resonance spectra of small volume elements of (13 mm)3 positioned in lumbar vertebral bodies have been investigated in 15 healthy persons of different ages and sexes and in 11 patients with leukemia using double spin-echo sequences. Signal intensities and positions of the spectral lines have been evaluated. Interindividual spectra of VOI located in the center of vertebral bodies, intraindividual spectra of central VOI in different vertebral bodies, and spectra of different localiza… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
48
2

Year Published

1994
1994
2015
2015

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 62 publications
(52 citation statements)
references
References 4 publications
2
48
2
Order By: Relevance
“…The LW by measuring the full-width at half-maximum of each signal is commonly presented in Hertz (10). LW was influenced by magnetic field inhomogeneities, which stem from bone trabeculae (22,23).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The LW by measuring the full-width at half-maximum of each signal is commonly presented in Hertz (10). LW was influenced by magnetic field inhomogeneities, which stem from bone trabeculae (22,23).…”
Section: Discussionmentioning
confidence: 99%
“…If the L3 vertebra was collapsed or otherwise altered in structure, a neighboring vertebra (L2) was used. The 1 H stimulated echo-acquisition mode (STEAM) sequence was used as described (10,20). A cubic voxel for spectral measurement was placed at third lumbar vertebral body ( Fig.…”
Section: H Mrs Measurementsmentioning
confidence: 99%
“…1b) using single voxel spectroscopy (SVS) with a stimulated echo-acquisition mode (STEAM) sequence for three-dimensional localization of the sample volume (the proton MRS STEAM sequence has been described elsewhere (15,19)). Automatic global shimming was performed prior to acquisition by an automated algorithm.…”
Section: Mri and Mrsmentioning
confidence: 99%
“…Proton MRS techniques have been developed and used to measure the musculoskeletal and fat tissue in vivo (13)(14)(15)(16)(17)(18). In 1995, Bluemke et al (13) measured fat content (as a percentage) in the femoral head by using MRS on patients with systemic lupus erythematosus, long-term corticosteroid treatment patients, and healthy subjects.…”
mentioning
confidence: 99%
See 1 more Smart Citation