2013
DOI: 10.1016/j.msec.2013.08.001
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric sensor based on carbon paste electrode modified with molecular imprinted polymer for determination of sulfadiazine in milk and human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(30 citation statements)
references
References 37 publications
0
30
0
Order By: Relevance
“…The amount of GO and MIPs coated onto the GCE influenced the sensitivity of the MIP sensor for glucose detection . The current response of the MIP sensors was investigated in 10 × 10 −3 m [Fe(CN) 6 ] 3−/4− and 0.1 × 10 −3 m glucose solution at ambient temperature.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The amount of GO and MIPs coated onto the GCE influenced the sensitivity of the MIP sensor for glucose detection . The current response of the MIP sensors was investigated in 10 × 10 −3 m [Fe(CN) 6 ] 3−/4− and 0.1 × 10 −3 m glucose solution at ambient temperature.…”
Section: Resultsmentioning
confidence: 99%
“…The amount of GO and MIPs coated onto the GCE influenced the sensitivity of the MIP sensor for glucose detection. [35] The current response of the MIP sensors was investigated in Figure 5a showed that the current response increased with the increase in the amount of GO coated onto the GCE. The equilibrium amount of GO was ≈4 µL, because excess amounts of GO affected electron transfer.…”
Section: Preparation Of Mip Sensormentioning
confidence: 99%
“…The K values of norfloxacin and ciprofloxacin to MIP 11 were 1.65 and 1.71, respectively. It was shown that MIP 11 prepared by 1:3 enrofloxacin/APTES had a better selectivity and adsorption capacity than MIP 9 and MIP 10 . The experimental results were in good agreement with the computational predictions.…”
Section: Validation and Application Of The Developed Methodsmentioning
confidence: 99%
“…Obviously large consumption of this antibiotic agent, however, can lead to environmental and public health problems. Several methods for sulfamethoxazole determination have already been described in the literature, including chromatographic methods coupled with different detectors 18,22,24, capillary electrophoresis [25,26], spectrophotometry [27,28], and electroanalytical methods [29][30][31][32][33][34][35][36][37][38][39]. It is possible to observe in the literature, however, that non-renewable surface devices for CPE application were applied.…”
Section: Introductionmentioning
confidence: 99%