Voltammetric Determination of Isoniazid in the Presence of Acetaminophen Utilizing MoS2-Nanosheet-Modified Screen-Printed Electrode

Abstract: We used MoS2 nanosheets (MoS2 NSs) for surface modification of screen-printed electrode (MoS2NSs-SPE) aimed at detecting isoniazid (INZ) in the presence of acetaminophen (AC). According to analysis, an impressive catalytic performance was found for INZ and AC electro-oxidation, resulting in an appreciable peak resolution (~320 mV) for both analytes. Chronoamperometry, differential pulse voltammetry (DPV), linear sweep voltammogram (LSV), and cyclic voltammetry (CV) were employed to characterize the electrochem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 42 publications
(14 citation statements)
references
References 54 publications
0
13
0
Order By: Relevance
“…The most common electrochemical system used for laboratory study is made up of a reference electrode, counter electrode, and a working electrode (sensing electrode) immersed in an electrolyte which measures the potential and current generated from oxidative or reductive reactions. The working principle behind electrochemical sensors involves the generation of electrical signals from the analyte of interest, which is affected by the concentration of the analyte [108][109][110][111][112].…”
Section: Development Of Electrochemical Dzn Sensorsmentioning
confidence: 99%
“…The most common electrochemical system used for laboratory study is made up of a reference electrode, counter electrode, and a working electrode (sensing electrode) immersed in an electrolyte which measures the potential and current generated from oxidative or reductive reactions. The working principle behind electrochemical sensors involves the generation of electrical signals from the analyte of interest, which is affected by the concentration of the analyte [108][109][110][111][112].…”
Section: Development Of Electrochemical Dzn Sensorsmentioning
confidence: 99%
“…Sunset yellow and other chemicals used were of analytical grade and were purchased from Merck. Flower-like MoS2 was synthesized in our laboratory [72]. A typical SEM is shown in Figure 1.…”
Section: Apparatus and Chemicalsmentioning
confidence: 99%
“…These methods are time-consuming, expensive and require complicated pre-treatment steps. On the other hand, the electrochemical methods are a very promising way for the determination of folic acid and other compounds due to easy fabrication, low cost and rapid analysis compared to other analytical methods [15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30].…”
Section: Introductionmentioning