2021
DOI: 10.2174/1573412916999200730234925
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric Determination of Diazepam on Antimony Film Screen- Printed Electrode in Pharmaceutical Formulations

Abstract: Background: Diazepam belongs to the group of 1,4-benzodiapines. It is used for the treatment of anxiety, convulsions and as a muscle relaxant. The presence of 4,5-azomethine group enables its electrochemical detection Introduction: A screen-printed electrode modified with antimony film was used for the determination of diazepam in pharmaceutical preparations Methods: Electrode modification was done by ex-situ deposition of antimony on commercially available screen-printed electrode. Parameters affecting th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 31 publications
0
3
1
Order By: Relevance
“…analyses and portable equipment. While the LOD of 2.0 μM for DZP attained by the proposed platform may not reach the same levels as those observed in previously published electrochemical methods, 25,29,31,50,[54][55][56][57][58][59][60][61]63 it has demonstrated adequacy for the determination of DZP in pharmaceuticals and alcoholic drinks purposely fortified with this drug. In these applications, the total amount of DZP is anticipated to exceed the LOD obtained in this study.…”
Section: Product Namecontrasting
confidence: 60%
See 2 more Smart Citations
“…analyses and portable equipment. While the LOD of 2.0 μM for DZP attained by the proposed platform may not reach the same levels as those observed in previously published electrochemical methods, 25,29,31,50,[54][55][56][57][58][59][60][61]63 it has demonstrated adequacy for the determination of DZP in pharmaceuticals and alcoholic drinks purposely fortified with this drug. In these applications, the total amount of DZP is anticipated to exceed the LOD obtained in this study.…”
Section: Product Namecontrasting
confidence: 60%
“…Comparison with other electroanalytical platforms.-Table IV illustrates the comparison between the proposed protocol and other electrochemical methods for DZP sensing. 25,27,29,31,50,[54][55][56][57][58][59][60][61][62][63] The data in this table reveal that only two documented studies utilized miniaturized screen-printed electrodes, one with carbon material in differential pulse adsorptive stripping voltammetric mode (DPAdSV) 27 and the other with an antimony film in LSV mode, 54 deviating from the conventional three-electrode system where individual electrodes are immersed separately into the analyzed solution. Furthermore, the most of electrochemical methods listed in Table IV employed chemically modified electrodes 29,31,54,55,[57][58][59][60][61]63 to amplify sensitivity and/or selectivity of DZP determination.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…2019 a layered double hydroxide/poly(tyrosine) film for electrochemical determination of diazepam [ 79 ]; 2021 an electrode for voltammetric determination of diazepam in pharmaceutical formulations [ 80 ].…”
Section: Routine and Improved Analyses Of Abused Substancesmentioning
confidence: 99%