2009
DOI: 10.1016/j.forsciint.2009.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric determination of cocaine in confiscated samples using a cobalt hexacyanoferrate film-modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
30
0
5

Year Published

2010
2010
2020
2020

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 54 publications
(35 citation statements)
references
References 21 publications
0
30
0
5
Order By: Relevance
“…However, interferences from substances which oxidise at potentials close to that observed for cocaine make the analysis more difficult. This difficulty has sometimes been solved by the modification of the working electrode with polymers, Schiff bases, or biomolecules which increase the sensitivity and provide selectivity to the electrochemical system (Table 1) [29][30][31][32][33][34][35][36][37]. Comparing the analytical parameters with those previously reported in the literature (see Table 1), it is clearly seen that the use of the PANI-β-CD/ fMWCNT film leads, in most cases, to comparable limits of detection.…”
Section: Analytical Applicationmentioning
confidence: 92%
“…However, interferences from substances which oxidise at potentials close to that observed for cocaine make the analysis more difficult. This difficulty has sometimes been solved by the modification of the working electrode with polymers, Schiff bases, or biomolecules which increase the sensitivity and provide selectivity to the electrochemical system (Table 1) [29][30][31][32][33][34][35][36][37]. Comparing the analytical parameters with those previously reported in the literature (see Table 1), it is clearly seen that the use of the PANI-β-CD/ fMWCNT film leads, in most cases, to comparable limits of detection.…”
Section: Analytical Applicationmentioning
confidence: 92%
“…Electroanalytical techniques have often been used for the analysis of a wide range of substances of industrial, pharmacological, and biomedical interest [14][15][16]23]. Voltammetry, for instance, consists in the application of a linear ramp of electrical potential between two electrodes (working and auxiliary) immersed in a liquid solution containing an analyte, with subsequent measurement of the produced electric current [20].…”
Section: Electroanalytical Methodologiesmentioning
confidence: 99%
“…38 This has included using cytochrome 39 P450, carbon nanotubes (CNTs) 40 , -cyclodextrin incorporated in polyaniline films with CNTs 41 , Schiff base films 42 , carbon paste electrodes modified with methoxy-substituted N-N'ethylenebis(salcylideneiminato)uranyl(VI) complexes and Pt disk electrodes modified with cobal thexacyanoferrate films. 43 However, the majority of these did not have the required sensitivity or specificity for widespread applications. To achieve this specificity, the main approach in recent work has been to incorporate either an aptamer or antibody specific or to use an alternative working electrode for cocaine detection.…”
Section: Chemical Detectionmentioning
confidence: 99%