2019
DOI: 10.1134/s0036024419060335
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric Determination of Ascorbic Acid in Pharmaceutical Formulations on a Boron Doped Diamond Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…The relative standard deviation was measured at two levels of concentration mass of AA, i.e., 45 μg L −1 and 158 μg L −1 and calculated to be 4.2 % and 3.8%, respectively, values indicating the good reproducibility of the proposed assay. The linear detection region of AA in the present study is in several cases better than that determined by the corresponding electrochemical techniques in the literature [ 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 45 ] On the other hand, the detection limit of the current analytical AA detection methodology is better compared to the majority of those determined with the other corresponding electrochemical techniques available in the literature, with the exception that it is in the same magnitude of Zhao et 2019 [ 20 ], Kaçar and Erden 2020 [ 2 ], Broncová et al 2021 [ 34 ], Pekin et al [ 45 ], as it can be seen from Table 1 .…”
Section: Analytical Performance Of the Proposed Assaymentioning
confidence: 48%
See 1 more Smart Citation
“…The relative standard deviation was measured at two levels of concentration mass of AA, i.e., 45 μg L −1 and 158 μg L −1 and calculated to be 4.2 % and 3.8%, respectively, values indicating the good reproducibility of the proposed assay. The linear detection region of AA in the present study is in several cases better than that determined by the corresponding electrochemical techniques in the literature [ 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 45 ] On the other hand, the detection limit of the current analytical AA detection methodology is better compared to the majority of those determined with the other corresponding electrochemical techniques available in the literature, with the exception that it is in the same magnitude of Zhao et 2019 [ 20 ], Kaçar and Erden 2020 [ 2 ], Broncová et al 2021 [ 34 ], Pekin et al [ 45 ], as it can be seen from Table 1 .…”
Section: Analytical Performance Of the Proposed Assaymentioning
confidence: 48%
“…Moreover, Pt modified electrodes with 3,4-diaminobenzoic acid and neutral red [ 34 ] or screen-printed electrodes (SPE) [ 35 , 36 , 37 ]. Furthermore, boron-dropped electrodes were also used [ 38 ]. Meanwhile, miniaturized nanoporous gold (NPG) [ 39 ], platinum functionalized with commercial pre-polymers electrodes [ 40 ] and yttrium hexacyanoferrate microflowers on freestanding three-dimensional graphene substrates [ 41 ] were also utilized in the detection of AA.…”
Section: Introductionmentioning
confidence: 99%
“…A comparison between the developed voltammetric method and some of the common analytical and voltammetric methods for ascorbic acid determination in terms of detection limit and the linear range was displayed in Table 3. As shown, the iodine-coated platinum electrode exhibited a lower detection limit than that of other voltammetric methods (34)(35)(36). In contrast, the obtained linear range was convenient and extended compared to other voltammetric methods.…”
Section: Pharmaceutical Preparation Analysismentioning
confidence: 82%
“…In a study by Vedenyapina et al [163], SWV and CV were carried out to analyze the electrochemical properties of AA on a boron-doped diamond (BDD) electrode. They found that the voltammetric response signal can be used to quantify AA content in the aqueous solution.…”
Section: Square Wave Voltammetry Methods To Detect Ascorbic Acidmentioning
confidence: 99%