2021
DOI: 10.1109/access.2021.3097001
|View full text |Cite
|
Sign up to set email alerts
|

Voltage Estimation of Active Distribution Network Using PMU Technology

Abstract: As the Distributed Generation (DG) is evolving, the distribution network has undergone tremendous change. The DG sources like wind and solar are intermittent in nature. Hence to estimate the Active distribution network's (ADN) parameters (Voltage and Current) accurately with the DG variation, the traditional offline method like long-term smart distribution network planning (with off-line variant) method is not feasible in terms of network's reliability and operation. In this work, an online voltage estimation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 30 publications
(28 reference statements)
0
4
0
Order By: Relevance
“…Table 2 shows the complete observability of these test feeders, and the requisite PMU counts and placements for the case studies on the modified IEEE 18-bus, 33-bus, and 69-bus networks. When ZI buses are considered in the design of PMU placement, the necessary number of PMUs is significantly reduced without affecting the system’s observability [ 31 35 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Table 2 shows the complete observability of these test feeders, and the requisite PMU counts and placements for the case studies on the modified IEEE 18-bus, 33-bus, and 69-bus networks. When ZI buses are considered in the design of PMU placement, the necessary number of PMUs is significantly reduced without affecting the system’s observability [ 31 35 ].…”
Section: Resultsmentioning
confidence: 99%
“…networks. When ZI buses are considered in the design of PMU placement, the necessary number of PMUs is significantly reduced without affecting the system's observability [31][32][33][34][35].…”
Section: Plos Onementioning
confidence: 99%
See 1 more Smart Citation
“…In this context, distribution network phasor measurement units (DPMUs) permit the development of high-precision and time-synchronized monitoring networks. This is a timely technology that completely aligns with the tenets of the current smart grid revolution [1], [2], [3], [4].…”
Section: Introductionmentioning
confidence: 99%