2013
DOI: 10.1002/etep.1739
|View full text |Cite
|
Sign up to set email alerts
|

Voltage control of emerging distribution systems with induction motor loads using robust LQG approach

Abstract: SUMMARYThis paper identifies a new mode called "critical voltage mode" in emerging distribution systems. The small-signal stability analysis indicates that load voltage dynamics significantly influence the damping of the newly identified mode. This mode has frequency of oscillation between the electromechanical and subsynchronous oscillation of power systems. A novel voltage controller is designed to damp this voltage mode of the system. The controller is designed using the linear quadratic Gaussian (LQG) meth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 26 publications
0
11
0
Order By: Relevance
“…One of the main reasons behind the design of a nonlinear controller for power systems is to extend the range of the operation of the controller. Other nonlinear oscillation damping controllers for power systems such as feedback linearized controllers give a good performance, but they have a limited operating range . The control proposed in this paper has a wide range of operation.…”
Section: Power System Controlmentioning
confidence: 99%
“…One of the main reasons behind the design of a nonlinear controller for power systems is to extend the range of the operation of the controller. Other nonlinear oscillation damping controllers for power systems such as feedback linearized controllers give a good performance, but they have a limited operating range . The control proposed in this paper has a wide range of operation.…”
Section: Power System Controlmentioning
confidence: 99%
“…Thus, robust control is necessary. A linear quadratic Gaussian controller with norm-bounded uncertainty has been found to work well (Roy et al, 2013b).…”
Section: Penetration Of Dgmentioning
confidence: 99%
“…This combination of conventional and renewable sources is called the isolated hybrid power system (IHPS) . Usually, synchronous generators and induction generators are chosen for diesel and wind turbines, respectively . Induction generators are increasingly used in renewable energy systems, particularly in wind power conversion systems.…”
Section: Introductionmentioning
confidence: 99%