Search citation statements
Paper Sections
Citation Types
Publication Types
Relationship
Authors
Journals
The merits of several high-resolution, pulsed-powerdriven, flash X-ray sources are examined with numerical simulation for voltages up to 10 MV. The charged particle dynamics in these self-magnetically pinched diodes (SMPDs), as well as electron scattering and energy loss in the high-atomic-number target, are treated with the partic by coupling the output from LSP with the two-dimensional component of the integrated tiger series of Monte Carlo electron/photon transport codes, CYLTRAN. The LSP/CYLTRAN model agrees well with angular dose-rate measurements from positive-polarity rod-pinch-diode experiments, where peak voltages ranged from 5.2-6.3 MV. This analysis indicates that, in this voltage range, the dose increases with angle and is a maximum in the direction headed back into the generator. This suggests that high-voltage rod-pinch experiments should be performed in negative polarity to maximize the extracted dose. The benchmarked LSP/CYLTRAN model is then used to examine three attractive negative-polarity diode geometry concepts as possible high-resolution radiography sources for voltages up to 10 MV. For a 2-mm-diameter reentrant rod-pinch diode (RPD), a forward-directed dose of 740 rad(LiF) at 1 m in a 50-ns full-width at half-maximum radiation pulse is predicted. For a 2-mm-diameter nonreentrant RPD, a forward-directed dose of 1270 rad(LiF) is predicted. For both RPDs, the on-axis X-ray spot size is comparable to the rod diameter. A self-similar hydrodynamic model for rod expansion indicates that spot-size growth from hydrodynamic effects should be minimal. For the planar SMPD, a forward-directed dose of 1370 rad(LiF) and a similar X-ray spot size are predicted. These results show that the nonreentrant RPD and the planar SMPD are very attractive candidates for negative-polarity high-resolution X-ray sources for voltages of up to 10 MV.Index Terms-Bremsstrahlung, coupled electron-photon transport, electron beams, flash X-radiography, high-power diodes, ion beams, Monte Carlo, particle-in-cell.
The merits of several high-resolution, pulsed-powerdriven, flash X-ray sources are examined with numerical simulation for voltages up to 10 MV. The charged particle dynamics in these self-magnetically pinched diodes (SMPDs), as well as electron scattering and energy loss in the high-atomic-number target, are treated with the partic by coupling the output from LSP with the two-dimensional component of the integrated tiger series of Monte Carlo electron/photon transport codes, CYLTRAN. The LSP/CYLTRAN model agrees well with angular dose-rate measurements from positive-polarity rod-pinch-diode experiments, where peak voltages ranged from 5.2-6.3 MV. This analysis indicates that, in this voltage range, the dose increases with angle and is a maximum in the direction headed back into the generator. This suggests that high-voltage rod-pinch experiments should be performed in negative polarity to maximize the extracted dose. The benchmarked LSP/CYLTRAN model is then used to examine three attractive negative-polarity diode geometry concepts as possible high-resolution radiography sources for voltages up to 10 MV. For a 2-mm-diameter reentrant rod-pinch diode (RPD), a forward-directed dose of 740 rad(LiF) at 1 m in a 50-ns full-width at half-maximum radiation pulse is predicted. For a 2-mm-diameter nonreentrant RPD, a forward-directed dose of 1270 rad(LiF) is predicted. For both RPDs, the on-axis X-ray spot size is comparable to the rod diameter. A self-similar hydrodynamic model for rod expansion indicates that spot-size growth from hydrodynamic effects should be minimal. For the planar SMPD, a forward-directed dose of 1370 rad(LiF) and a similar X-ray spot size are predicted. These results show that the nonreentrant RPD and the planar SMPD are very attractive candidates for negative-polarity high-resolution X-ray sources for voltages of up to 10 MV.Index Terms-Bremsstrahlung, coupled electron-photon transport, electron beams, flash X-radiography, high-power diodes, ion beams, Monte Carlo, particle-in-cell.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.