2011
DOI: 10.1152/ajpregu.00173.2011
|View full text |Cite
|
Sign up to set email alerts
|

Visualizing ocular lens fluid dynamics using MRI: manipulation of steady state water content and water fluxes

Abstract: Vaghefi E, Pontre BP, Jacobs MD, Donaldson PJ. Visualizing ocular lens fluid dynamics using MRI: manipulation of steady state water content and water fluxes. Am J Physiol Regul Integr Comp Physiol 301: R335-R342, 2011. First published May 18, 2011 doi:10.1152/ajpregu.00173.2011.-Studies using various MRI techniques have shown that a water-protein concentration gradient exists in the ocular lens. Because this concentration is higher in the core relative to the lens periphery, a gradient in refractive index is… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

5
72
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 61 publications
(77 citation statements)
references
References 30 publications
(42 reference statements)
5
72
0
Order By: Relevance
“…In the above equation, T1 values are extracted by applying a train of TI values (20,50, 80, 100, 150, 200, 250, 300, 350, and 400 ms) to obtain 10 data points which were then fitted with a monoexponential curve using a nonlinear curve fitting routine (EZYFIT, in the public domain, http://www.fast.u-psud.fr/ezyfit/). EZYFIT uses a recursive process and unconstrained nonlinear minimization of the sum of squared residuals, to find the optimum fit.…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%
See 3 more Smart Citations
“…In the above equation, T1 values are extracted by applying a train of TI values (20,50, 80, 100, 150, 200, 250, 300, 350, and 400 ms) to obtain 10 data points which were then fitted with a monoexponential curve using a nonlinear curve fitting routine (EZYFIT, in the public domain, http://www.fast.u-psud.fr/ezyfit/). EZYFIT uses a recursive process and unconstrained nonlinear minimization of the sum of squared residuals, to find the optimum fit.…”
Section: Magnetic Resonance Imagingmentioning
confidence: 99%
“…In a previous study using T1 weighted imaging we showed that inhibiting the circulation system in the bovine lenses by either incubating them in AAH-High K þ , or low temperature, abolished the inherent water gradient and increased the water content in the lens core. 20 In this study, we have complemented our existing T1 imaging results and introduced T2 imaging to determine whether the observed increase in water content induced by inhibiting the lens microcirculation changes overall lens geometry and the GRIN, both key determinants of the optical properties of the lens. In the current study, in addition to inhibiting the circulation system by incubating lenses in AAH-High K þ to depolarize the lens potential, we have incubated lenses in ouabain to specifically block Na þ pump activity, which is known to drive the microcirculation system.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…Also, some other studies demonstrated that MRI could be used as an effective method to diffusivity mapping of the lens (24)(25)(26). On the other hand, the positive use of MRI in real-time measurements of water transport in the lens has been reported by previous studies (27)(28)(29). Sheppard et al showed the successful use of MRI for the measurement of mean crystalline lens thickness during accommodation (13).…”
Section: Discussionmentioning
confidence: 99%