2010
DOI: 10.1111/j.1467-8659.2009.01665.x
|View full text |Cite
|
Sign up to set email alerts
|

Visual Support for Interactive Post‐Interventional Assessment of Radiofrequency Ablation Therapy

Abstract: Teaser Figure: A volume rendering with the corresponding tumor map, a pseudo-cylindrical mapping of the tumor surface.Percutaneous radiofrequency (RF) ablation is a minimally invasive, image-guided therapy for the treatment of liver tumors. The assessment of the ablation area (coagulation) is performed to verify the treatment success as an essential part of the therapy. Traditionally, pre-and post-interventional CT images are used to visually compare the shape, size, and position of tumor and coagulation. In t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 27 publications
0
23
0
Order By: Relevance
“…In the research of Rieder et al [45], the tumour map is used as a visualisation and interaction technique for evaluation of post-interventional coagulation areas resulting from radiofrequency ablation. Based on our previous studies of the comparison of MWA and radiofrequency ablation [46], we consider that this tumour mapping technique is equally applicable to evaluating post-interventional coagulation areas resulting from MWA.…”
Section: Planning Navigation and Evaluationmentioning
confidence: 99%
See 3 more Smart Citations
“…In the research of Rieder et al [45], the tumour map is used as a visualisation and interaction technique for evaluation of post-interventional coagulation areas resulting from radiofrequency ablation. Based on our previous studies of the comparison of MWA and radiofrequency ablation [46], we consider that this tumour mapping technique is equally applicable to evaluating post-interventional coagulation areas resulting from MWA.…”
Section: Planning Navigation and Evaluationmentioning
confidence: 99%
“…This zone is the optimal simulation MWA result inside the safety margin. Based on the research of Rieder et al [45], the GUI of 3D visualisation for operational evaluation is shown in Figure 7.…”
Section: Planning Navigation and Evaluationmentioning
confidence: 99%
See 2 more Smart Citations
“…As soon as the analysis of the spike signals indicates that the MER electrodes are in the target region, green beads are rendered that draw attention to those structures. Furthermore, this color coding resembles the traffic light color scheme proposed by Rieder et al [30], which intuitively assigns green to good areas, while red is assigned to bad areas. To further reduce visual clutter only one bead is rendered for all electrodes.…”
Section: Additions To the Contextual Viewmentioning
confidence: 99%