2017
DOI: 10.1016/j.ejmp.2017.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Virtual patient 3D dose reconstruction using in air EPID measurements and a back-projection algorithm for IMRT and VMAT treatments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
42
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 34 publications
(43 citation statements)
references
References 35 publications
1
42
0
Order By: Relevance
“…Other assemblies furnish dosimetric data corresponding to the gantry position using phantoms characterized by opportune geometries or rotation capability, as SunNuclear ArcCHECK ® , Scandidos Delta4 ® phantom, the IBA Compass, and PTW Octavius ® ‐4D. Many studies report a comparison of these devices, assessing their different responses as well as their ability in detecting intentional errors,4, 5, 6 or they were used in the validation process of novel QA strategies 7, 8. The present study is focused on PTW Octavius ® ‐4D.…”
Section: Introductionmentioning
confidence: 99%
“…Other assemblies furnish dosimetric data corresponding to the gantry position using phantoms characterized by opportune geometries or rotation capability, as SunNuclear ArcCHECK ® , Scandidos Delta4 ® phantom, the IBA Compass, and PTW Octavius ® ‐4D. Many studies report a comparison of these devices, assessing their different responses as well as their ability in detecting intentional errors,4, 5, 6 or they were used in the validation process of novel QA strategies 7, 8. The present study is focused on PTW Octavius ® ‐4D.…”
Section: Introductionmentioning
confidence: 99%
“…20 Also, in the initial investigation of the non-transit dose reconstruction algorithm used in this study, 19 an average 3G3 γ-pass rate value of 98.5% was reported for 5 IMRT and 5 VMAT plans. 20 Also, in the initial investigation of the non-transit dose reconstruction algorithm used in this study, 19 an average 3G3 γ-pass rate value of 98.5% was reported for 5 IMRT and 5 VMAT plans.…”
Section: Transit Epid Non-transit Epidmentioning
confidence: 86%
“…19 In IMRT reconstructions, the non-transit algorithm uses accumulated in air portal images to estimate the accumulated "virtual" transit primary portal dose distribution corresponding to each field.…”
Section: D | 3d Non-transit Epid Dosimetrymentioning
confidence: 99%
See 2 more Smart Citations