2006
DOI: 10.1002/cyto.b.20148
|View full text |Cite
|
Sign up to set email alerts
|

“Virtual flow cytometry” of immunostained lymphocytes on microscopic tissue slides: iHCFlow™ tissue cytometry

Abstract: Background: A method and approach is developed for fully automated measurements of immunostained lymphocytes in tissue sections by means of digital color microscopy and patent pending advanced cell analysis. The validation data for population statistic measurements of immunostained lymphocytes in tissue sections using tissue cytometry (TC) is presented. The report is the first to describe the conversion of immunohistochemistry (IHC) data to a flow cytometry-like two parameter dot-plot display, hence the techni… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2008
2008
2014
2014

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(2 citation statements)
references
References 36 publications
0
2
0
Order By: Relevance
“…This method automatically converts digital images of immunostained tissue to percentage positive, using a multithresholding, iterative bit slice identification of stained nuclei and unstained nuclei. The single cell count results correlate with both manual Ki-67 scoring and standardized tissue flow cytometry results (3). Briefly, thymic sections, previously immunostained as described, using Ki-67 AP-DAB (Mib-1, Ventana) by automated Ventana XT (Tucson, AZ, USA) are put on the stage (2).…”
Section: Methodsmentioning
confidence: 93%
“…This method automatically converts digital images of immunostained tissue to percentage positive, using a multithresholding, iterative bit slice identification of stained nuclei and unstained nuclei. The single cell count results correlate with both manual Ki-67 scoring and standardized tissue flow cytometry results (3). Briefly, thymic sections, previously immunostained as described, using Ki-67 AP-DAB (Mib-1, Ventana) by automated Ventana XT (Tucson, AZ, USA) are put on the stage (2).…”
Section: Methodsmentioning
confidence: 93%
“…Although this assessment has been of blood and bone marrow smears, the automated immunostainer could, in theory, also be used to phenotype other fresh cell samples such as fine needle aspirates, tissue imprints and cytocentrifuge preparations 11. Further developments with this technology could include the utilisation of image analysis software to provide objective interpretation of the percentage of positive cells, and double staining for dual antigen expression 12. These technologies, currently under development, would provide objective “virtual flow cytometry” for cell smear staining.…”
Section: Discussionmentioning
confidence: 99%