2005
DOI: 10.1149/1.1887193
|View full text |Cite
|
Sign up to set email alerts
|

Viewing Asperity Behavior under the Wafer during CMP

Abstract: Recent experimental advances using dual emission laser induced fluorescence and image processing have provided high spatial and temporal resolution maps of the slurry layer during chemical mechanical polishing ͑CMP͒. Intensity differences in the images correspond to fluid layer thickness variations as the slurry passes between different pad and wafer topographies. Asperities expand under 14 µm deep wells and are compressed beyond the trailing edge of the well. Air pockets travel from the leading to the trailin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 9 publications
0
7
0
Order By: Relevance
“…Philipossian's group modified this tool with high spatial resolution images, high-intensity UV laser pulses, and enhanced fluorescence [Fig. 2(a)] [24]. They used two different fluorescent dyes that can be excited at different wavelengths and recorded the fluorescence intensities of the dye molecules in the slurry using two high-resolution cameras.…”
Section: Lubrication Modelsmentioning
confidence: 99%
See 2 more Smart Citations
“…Philipossian's group modified this tool with high spatial resolution images, high-intensity UV laser pulses, and enhanced fluorescence [Fig. 2(a)] [24]. They used two different fluorescent dyes that can be excited at different wavelengths and recorded the fluorescence intensities of the dye molecules in the slurry using two high-resolution cameras.…”
Section: Lubrication Modelsmentioning
confidence: 99%
“…The intensity ratio of light detected by each camera was converted to slurry film thickness after proper calibration [Fig. 2(a)] [23,24]. They also studied the dependence of the slurry film thickness on the type of conditioner disk (design, kinematics, and pressure) [26] and pad properties (asperities, roughness, and groove) [25].…”
Section: Lubrication Modelsmentioning
confidence: 99%
See 1 more Smart Citation
“…DELIF is used to measure the fluid, i.e. slurry layer thickness, between the wafer and pad surfaces [16][17][18]. High-intensity (brighter) areas on a DE-LIF image represent valleys between asperities in which the fluid layer is the thickest.…”
Section: Introductionmentioning
confidence: 99%
“…Since then, DELIF has been used to attain spatially and temporally averaged values for variables that include pH [6], temperature [6,7] and slurry film thickness [8]. Recently the technique has been refined such that we can now capture high spatial and temporal resolution images during CMP [9]. This paper will explore the feasibility of studying pad characteristics such as mean asperity compression and pad surface roughness based upon slurry film thickness measurements.…”
Section: Introductionmentioning
confidence: 99%