Video Ambulatory EEG in Children: A Quality Improvement Study

Abstract: Purpose:We implemented a video ambulatory EEG (VA-EEG) Program as an alternative to inpatient video EEG monitoring for some patients given potential benefits related to quicker access, greater convenience, and lower cost. To evaluate the newly initiated program, we performed a quality improvement study to assess whether VA-EEG yielded studies with interpretable EEG and video quality that generated clinically beneficial data.Methods:This was a single-center prospective quality improvement study. We surveyed ord… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…Neither longer EEG duration nor preselecting event frequency significantly improved A-EEG yield. Interestingly, three studies used video telemetry, 4–6 but their outcome was not significantly different from the other studies (events captured in 58% to 64%, answered the posed question in 59% to 77%). Including our findings, overall A-EEG was able to answer the posed question in 59% to 88% of patients (mean 71%, median 73%, SD 8.5).…”
Section: Resultsmentioning
confidence: 89%
See 4 more Smart Citations
“…Neither longer EEG duration nor preselecting event frequency significantly improved A-EEG yield. Interestingly, three studies used video telemetry, 4–6 but their outcome was not significantly different from the other studies (events captured in 58% to 64%, answered the posed question in 59% to 77%). Including our findings, overall A-EEG was able to answer the posed question in 59% to 88% of patients (mean 71%, median 73%, SD 8.5).…”
Section: Resultsmentioning
confidence: 89%
“…Unfortunately, out of 43 reported events, 17 (39.5%) were poorly or not seen on video. 6 Indeed, one possible explanation for the similar successful rates obtained by A-EEG with and without video is that patients may move out of the camera's range during the suspicious events. [4][5][6]14 Over time, when A-EEG with synchronized video technology becomes widely available, we may have more robust data regarding its helpfulness in clinical practice.…”
Section: Despite the Lack Of Synchronous Video Analysis Along Withmentioning
confidence: 89%
See 3 more Smart Citations