Vibrotactile Stimulation System to Treat Apnea of Prematurity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
21
0
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(23 citation statements)
references
References 7 publications
1
21
0
1
Order By: Relevance
“…The sample size ranged from one to four infants with a median of four infants. The mean GA varied between studies from 28 to 31.25 weeks and the mean birth weight varied from 1,280 to 1,495.5 g. Two studies only reported inclusion criteria instead of mean values for GA and birth weight ( 19 , 22 ). In one study, aminophylline was administered during the study, which started 7 days after birth ( 23 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The sample size ranged from one to four infants with a median of four infants. The mean GA varied between studies from 28 to 31.25 weeks and the mean birth weight varied from 1,280 to 1,495.5 g. Two studies only reported inclusion criteria instead of mean values for GA and birth weight ( 19 , 22 ). In one study, aminophylline was administered during the study, which started 7 days after birth ( 23 ).…”
Section: Resultsmentioning
confidence: 99%
“…Heavy workload and alarm fatigue might have a negative influence on prompt and adequate treatment of apneas ( 18 ). The longer the delay in response time, the longer the total duration of apnea and the lower the peripheral oxygen saturation (SpO 2 ) values ( 19 ). Also, administration of tactile stimulation increases the risks of infection due to cross-contamination and will interrupt sleep, which can be disadvantageous for the growth and development of the infant ( 20 ).…”
Section: Introductionmentioning
confidence: 99%
“…O estímulo vibratório obteve sucesso em 56% das tentativas de reversão das apnéias. 12 No presente estudo, foram utilizados somente dois parâmetros fisiológicos a FP e a SpO2, que se mostraram eficazes nesta detecção. A tecnologia proposta pode gerar vantagens, por utilizar, somente, o oxímetro de pulso para a detecção da apnéia, um equipamento rotineiramente incorporado no manejo da apnéia nas terapias intensivas em nosso meio, agregando um novo valor tecnológico, quando acoplado ao sistema de reversão da apnéia.…”
Section: Recém-nascido Estímulo Vibratóriounclassified
“…The more the response time is extended, the more difficult it is to stop the episode of AB leading to significant problems and consequences that may be irreversible. The average response time delay, measured from the activation of the alarm until the application of the therapy, was estimated around 33 s, with an average of 13 s of tactile stimulation for the AB event suppression (Pichardo et al 2003). Hence the algorithm that activates the alarm has a crucial role in the early detection of respiratory arrest.…”
Section: Introductionmentioning
confidence: 99%