2014
DOI: 10.1007/978-3-319-08413-8_12
|View full text |Cite
|
Sign up to set email alerts
|

Vibration Mitigation of Wind Turbine Towers with Tuned Mass Dampers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 10 publications
0
6
0
1
Order By: Relevance
“…In order to reduce the effects of the resonance phenomenon (alternate variation of the top displacement, which increase in time) described in the previous Sections, two different solutions have been considered: (i) the installation of a damping device and (ii) the modification of the steel tower height, resulting in a change of the eigenfrequencies. In literature, the use of active or passive mass dampers is described [33,34]. In this work, as a first solution, a TMD is considered.…”
Section: Mitigation Of Vibrationmentioning
confidence: 99%
“…In order to reduce the effects of the resonance phenomenon (alternate variation of the top displacement, which increase in time) described in the previous Sections, two different solutions have been considered: (i) the installation of a damping device and (ii) the modification of the steel tower height, resulting in a change of the eigenfrequencies. In literature, the use of active or passive mass dampers is described [33,34]. In this work, as a first solution, a TMD is considered.…”
Section: Mitigation Of Vibrationmentioning
confidence: 99%
“…In diesem Beitrag wird vor allem auf die Eigendämpfung des Flüssigkeitstilgers selbst sowie auf den Einfluss dieser Dämpfung auf das schwingende Hauptsystem eingegangen. Für eine effektive Wirkung des Schwingungsdämpfers ist die Abstimmung seiner dynamischen Parameter auf die Eigenschaften des Hauptsystems (Schornsteine, Windkraftanlagen) essenziell [11, 13, 15, 16, 17]. Meist werden hierfür die Abstimmungskriterien nach D EN H ARTOG angewendet [10].…”
Section: Dämpfungunclassified
“…In the aspect of using TMD, Stewart and Lackner [14] examined the performance of tuned mass damper (TMD) on the vibration control of wind turbines, and the results demonstrated that the TMD could reduce tower fatigue load efficiently, particularly in side-to-side directions. Altay et al [15] utilized TMD to mitigate the seismic-induced vibration of the wind turbine tower considering soil-structure interaction. e results showed that TMD could reduce resonant tower vibrations and improve the fatigue life of wind turbines effectively.…”
Section: Introductionmentioning
confidence: 99%