2018
DOI: 10.1016/j.actaastro.2017.11.038
|View full text |Cite
|
Sign up to set email alerts
|

Vibration isolation and dual-stage actuation pointing system for space precision payloads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(13 citation statements)
references
References 29 publications
0
13
0
Order By: Relevance
“…Note that this additional dynamics was the main restriction to design the DVF of Eq. (16). The third one is the similar value of c, which is 0.78 for the experimental, whereas for the numerical simulation it is 0.80.…”
Section: Vibration Isolation Effect On the Base Structurementioning
confidence: 53%
See 1 more Smart Citation
“…Note that this additional dynamics was the main restriction to design the DVF of Eq. (16). The third one is the similar value of c, which is 0.78 for the experimental, whereas for the numerical simulation it is 0.80.…”
Section: Vibration Isolation Effect On the Base Structurementioning
confidence: 53%
“…The control force in AVI systems is not only generated as a reaction of the relative movement between base and platform but an actuator is located between them, allowing application of an additional control force by the use of feedback or feedforward control techniques. This makes AVI systems the most suitable for many applications [2,16,18,25]. However, it is necessary to deal with some additional challenges of AVI, such as instability of the control system, real-time signal processing, the inherent isolator dynamics and the influence of the control force on the support structure.…”
Section: Introductionmentioning
confidence: 99%
“…The VCM works well in the frequency of zero to tens of Hertz, but its high frequency dynamics is not good enough [16]. Moreover, for the micro vibration isolation, the resolution of the VCM is not high enough as well [17], [18].…”
Section: Introductionmentioning
confidence: 99%
“…At present, the research on positioning and vibration isolation platform is divided into two types, namely, micropositioning and vibration isolation platform and macro-and microcombined platform [13]. e most studied active vibration isolation platform is based on the Stewart configuration [14][15][16], followed by the noncontact vibration isolation platform based on Lorentz force actuators [12,[17][18][19][20]. In addition, there are microvibration active vibration isolation platforms designed according to other different working principles of actuators [21][22][23][24][25].…”
Section: Introductionmentioning
confidence: 99%