International Symposium on Electromagnetic Compatibility - EMC EUROPE 2012
DOI: 10.1109/emceurope.2012.6396655
|View full text |Cite
|
Sign up to set email alerts
|

Vibrating Intrinsic Reverberation Chambers for shielding effectiveness measurements

Abstract: A new technique for shielding effectiveness measurements is the dual VIRC method. In this method two Vibrating Intrinsic Reverberation Chambers (VIRC) are combined together via a common wall with an aperture that forms the interface between them. This particular set-up makes it possible to achieve a very high dynamic range. Advantage of this technique compared to the nested reverberation set-up is that measurements can be conducted much faster and at much lower frequency. Several different approaches to determ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
35
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 19 publications
(35 citation statements)
references
References 6 publications
(14 reference statements)
0
35
0
Order By: Relevance
“…4 shows the SE values obtained from the CCM after the evaporation process is completed. As expected, the SE values are considerably lower than the first one, with a maximum value equal to 2 dB around high frequencies (14)(15)(16)(17)(18). It is important to note that in order to verify the uncertainty related to the repeatability of the proposed procedure, measurements of the CCM have been evaluated, removed from setup, reinserted and evaluated again.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…4 shows the SE values obtained from the CCM after the evaporation process is completed. As expected, the SE values are considerably lower than the first one, with a maximum value equal to 2 dB around high frequencies (14)(15)(16)(17)(18). It is important to note that in order to verify the uncertainty related to the repeatability of the proposed procedure, measurements of the CCM have been evaluated, removed from setup, reinserted and evaluated again.…”
Section: Resultsmentioning
confidence: 99%
“…The IEC 61000-4-21 standard [9] describes a particular approach to use the RC, the nested RCs approach, i.e., a smaller RC within a bigger RC, for measuring the SE of materials. Different research groups apply this technique to evaluate the SE of civil engineering materials [10][11][12][13][14]. The first formulation for the SE of the material under test (MUT) proposed in [10] has been improved during the years by considering new effective procedures which overcomes the drawbacks of the earlier ones.…”
Section: The Rc Measurements Methodsmentioning
confidence: 99%