2010
DOI: 10.1016/j.ejso.2010.05.011
|View full text |Cite
|
Sign up to set email alerts
|

Vessel probe CT protocol in the study of esophageal carcinoma: Can it improve preoperative T staging?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…In case of intestinal ischemia, MPR and 3D reconstructions allow to easily detect CT findings. In fact, such reconstructions as curved MPR, MIP, Vessel Probe (VP), SS-VRT, Tissue Transition Projections (TTP) are particularly useful for the assessment of the vascular and bowel signs of intestinal ischemia [20,21]. illustration of CT volumetric data from any desired perspective and provides 3D images which are significantly superior to other volume rendering techniques [13e15].…”
Section: Discussionmentioning
confidence: 99%
“…In case of intestinal ischemia, MPR and 3D reconstructions allow to easily detect CT findings. In fact, such reconstructions as curved MPR, MIP, Vessel Probe (VP), SS-VRT, Tissue Transition Projections (TTP) are particularly useful for the assessment of the vascular and bowel signs of intestinal ischemia [20,21]. illustration of CT volumetric data from any desired perspective and provides 3D images which are significantly superior to other volume rendering techniques [13e15].…”
Section: Discussionmentioning
confidence: 99%
“…It can display images in a variety of formats, including automatic and simultaneous orthogonal cross-sections, orthogonal MPR, oblique and curved MPR, 3D and curved reformat views. This fast and simple-to-use software has already been applied for examining the gastric and esophageal walls on contrast-enhanced MDCT (10, 11). Starting from simple transverse images, VP in MPR mode automatically generates a reference line along the major axis of structures with the maximum enhancement values and displays the best views in multiple curved planes.…”
Section: Methodsmentioning
confidence: 99%
“…CT images were evaluated by applying the Vessel Probe (VP) in MPR reconstructions and the automatic 3D analysis software which respectively provided peri-gastric lymph nodes qualitative and quantitative data [3], [16].…”
Section: Image Analysismentioning
confidence: 99%
“…By clicking on the lymph node site in simple transverse images, VP in MPR mode automatically generates a reference line along the major axis of lymph node and displays the best views in multiple curved planes [3], [16].…”
Section: Image Analysismentioning
confidence: 99%