2009 International Conference on Signal Processing Systems 2009
DOI: 10.1109/icsps.2009.43
|View full text |Cite
|
Sign up to set email alerts
|

Very High Resolution Digital Instantaneous Frequency Measurement Receiver

Abstract: The fine frequency estimation of received signal is very important in Electronic Warfare and communication systems. The performance of radar classification depends on the accuracy of frequency measurements. Since frequency measurement accuracy in Digital Instantaneous Frequency Measurement receiver is highly dependent on corresponding pulse detection technique, here we propose an improved approach which is able to detect pulses as narrow as 50 nsec. Simulation results confirm that this receiver is capable of d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…According to (1), (4), (5) and 6, we need to know λ and the measured φ 1,3 and φ 2,4 . λ can be achieved by the instantaneous frequency measurement (DIFM) [12] module in the radio frequency (RF) receiver and φ 1,3 , φ 2,4 obtained by the fast Fourier transform (FFT) or via a phase detector [13] is represented in full bit width (L-bit). As long as they are accurate enough, the DOA estimation accuracy will be maintained.…”
Section: Improved Methods Based On Lut 31 System Architecturementioning
confidence: 99%
“…According to (1), (4), (5) and 6, we need to know λ and the measured φ 1,3 and φ 2,4 . λ can be achieved by the instantaneous frequency measurement (DIFM) [12] module in the radio frequency (RF) receiver and φ 1,3 , φ 2,4 obtained by the fast Fourier transform (FFT) or via a phase detector [13] is represented in full bit width (L-bit). As long as they are accurate enough, the DOA estimation accuracy will be maintained.…”
Section: Improved Methods Based On Lut 31 System Architecturementioning
confidence: 99%
“…The targeting accuracy of frequency discrimination for the DFD correlator is 1.5 MHz, RMS. The frequency accuracy of the typical DFD system including digital processing part is about RMS 2.5 MHz [2]. LDFD unambiguous frequency is 5,120 MHz and HDFD unambiguous frequency is 13,920 MHz.…”
Section: Design Of Phasementioning
confidence: 99%
“…An earlier generation of electronic support (ES) systems was based on instantaneous frequency measurement (IFM) receiver and pulse measurement using log video. The timedomain technique was used for noise estimation and signal detection 6 and frequency were measured using time-frequency analysis [7][8][9] . But during conversion from radio frequency (RF) or intermediate frequency (IF) to log video, the phase and hence the modulation information is lost.…”
Section: Introductionmentioning
confidence: 99%