2019
DOI: 10.1016/j.applthermaleng.2018.12.074
|View full text |Cite
|
Sign up to set email alerts
|

Ventilation potential of an absorber-partitioned air channel solar chimney for diurnal use under Mexican climate conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(3 citation statements)
references
References 43 publications
0
3
0
Order By: Relevance
“…For the induced flow rate for ventilation, depending on the dimensions of the solar chimneys and the tested houses or buildings, the number of air changes per hour, denoted ''ACH,'' varied from a range of 6-15 for small test houses (Bansal et al, 2005;Khedari et al, 2000;Zavala-Guille´n et al, 2019) to 3.5-4.0 for real buildings (Asadi et al, 2016;Zavala-Guille´n et al, 2019). Those values of ACH comply with the minimum requirement of 1.3 recommended by ASHRAE standard 62-2 (ASHRAE, 2013).…”
Section: Solar Chimney For Natural Ventilation and Cooling Of Buildingsmentioning
confidence: 99%
“…For the induced flow rate for ventilation, depending on the dimensions of the solar chimneys and the tested houses or buildings, the number of air changes per hour, denoted ''ACH,'' varied from a range of 6-15 for small test houses (Bansal et al, 2005;Khedari et al, 2000;Zavala-Guille´n et al, 2019) to 3.5-4.0 for real buildings (Asadi et al, 2016;Zavala-Guille´n et al, 2019). Those values of ACH comply with the minimum requirement of 1.3 recommended by ASHRAE standard 62-2 (ASHRAE, 2013).…”
Section: Solar Chimney For Natural Ventilation and Cooling Of Buildingsmentioning
confidence: 99%
“…From the literature review on the previous research in Indonesia on solar chimney, the researcher in this study found a research about passive application of solar induction ventilation for sustainable building in the equator line [13]. The method of this research is mathematic model to calculate the potentials of chimney ventilation in residential house.…”
Section: B State Of the Art In Indonesiamentioning
confidence: 99%
“…It is still unknown if a solar chimney can offer enough natural ventilation under typical weather conditions to fulfill the requirement of the airborne infection isolation room suggested by WHO, namely 6 ACH. Zavala-Guillen et al [19] obtained that a solar chimney can offer a 7.9-11.4 ACH natural ventilation for a 27 m 3 room under typical weather conditions in Mexico. Hashmi et al [20] optimized solar chimney design in a house based on energy saving.…”
Section: Introductionmentioning
confidence: 99%