2012
DOI: 10.1007/978-3-642-31686-9_32
|View full text |Cite
|
Sign up to set email alerts
|

Vein Identification and Localization for Automated Intravenous Drug Delivery System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…In 2012, Prabhu et al [11] used two different approaches based on a NIR web-camera at a distance of 14 cm, and a DSLR (Digital Single Lens Reflex) camera with an external filter to block visible light, to aid intravenous delivery of haemostatic agent. The experiments focused on visualization of veins in the palm with the DSLR images having better performance.…”
Section: A Perception: Vein Visualization and Localizationmentioning
confidence: 99%
See 1 more Smart Citation
“…In 2012, Prabhu et al [11] used two different approaches based on a NIR web-camera at a distance of 14 cm, and a DSLR (Digital Single Lens Reflex) camera with an external filter to block visible light, to aid intravenous delivery of haemostatic agent. The experiments focused on visualization of veins in the palm with the DSLR images having better performance.…”
Section: A Perception: Vein Visualization and Localizationmentioning
confidence: 99%
“…Different imaging and visualization systems are part of this group. For example, Prabhu et al demonstrated an IR guidance system for vein localization [11]. Kopac et al [52] presented usability experiments with the SonixGPS device by Ultrasonix Medical Corp., Canada.…”
Section: A Low Level Autonomymentioning
confidence: 99%
“…For nearly 80 percent of all those receiving in-and out-patient treatment, intravenous catheters need to be installed to draw or transfuse blood, deliver drugs, and infuse fluids [9,10]. In the study [11], the high failure rate of approximately 14 million cases on the first attempt out of 500 million annual insertions is concerning.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, compared to human arms, automated injection for a mouse tail vein shows significantly greater challenges. Improved upon the image processing algorithms for human arm vein [8]–[12], an optimal image processing algorithm for mouse tail veins has been proposed [13]. …”
Section: Introductionmentioning
confidence: 99%