2020
DOI: 10.1002/jrs.5835
|View full text |Cite
|
Sign up to set email alerts
|

Vector casting for noise reduction

Abstract: We report a new method for the reduction of noise from spectra. This method is based on casting vectors from one data point to the following data points of the noisy spectrum. The noise‐reduced spectrum is computed from the casted vectors within a margin that is identified by an envelope‐finder algorithm. We compared here the presented method with the Savitzky–Golay and the wavelet transform approaches for noise reduction using simulated Raman spectra of various signal‐to‐noise ratios between 1 and 25 dB and e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 43 publications
0
8
0
Order By: Relevance
“…We modeled the noise spectrum N()ν¯ as the summation of shot noise, thermal noise, and readout noise, as described in detail in our previous work. [ 21 ] Different noise levels were generated to imitate spectra with different signal‐to‐noise ratio (SNR). italicSNR=falseν0.25em¯=00.25emcm1falseν¯=42000.25emcm1Rfalseν¯2dfalseν¯falseν0.25em¯=00.25emcm1falseν¯=42000.25emcm1Nfalseν¯2dfalseν¯ Training Dataset A contains 300 000 simulated raw spectra r()ν¯.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…We modeled the noise spectrum N()ν¯ as the summation of shot noise, thermal noise, and readout noise, as described in detail in our previous work. [ 21 ] Different noise levels were generated to imitate spectra with different signal‐to‐noise ratio (SNR). italicSNR=falseν0.25em¯=00.25emcm1falseν¯=42000.25emcm1Rfalseν¯2dfalseν¯falseν0.25em¯=00.25emcm1falseν¯=42000.25emcm1Nfalseν¯2dfalseν¯ Training Dataset A contains 300 000 simulated raw spectra r()ν¯.…”
Section: Methodsmentioning
confidence: 99%
“…Details on how the spectra were recorded and details about the equipment used can be found in our previous work. [ 21 ] The spectra cover a Raman shift range from 200 to 2000 cm −1 .…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…b shows the kinetics of the growth and the shrinkage of both peaks. With respect to the three examples provided above, the successful realization of the Raman measurements depends to a certain extend on the specific design of the Raman probe and on the processing of the obtained raw Raman spectra, which are main competences of the research team of Andreas Braeuer at TU Bergakademie Freiberg , .…”
Section: Liquid‐liquid Separation Systemsmentioning
confidence: 99%