2001
DOI: 10.1016/s0167-8140(01)00352-8
|View full text |Cite
|
Sign up to set email alerts
|

Variations of intracavitary applicator geometry during multiple HDR brachytherapy insertions in carcinoma cervix and its influence on reporting as per ICRU report 38

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
35
0
1

Year Published

2003
2003
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 53 publications
(38 citation statements)
references
References 11 publications
2
35
0
1
Order By: Relevance
“…Interand intrafraction deformations of prostate, bladder and rectum have been studied, [42][43][44][45][46] and the dosimetric impact owing to more general anatomical variations has been evaluated in a multicentre comparison of cervix BT. 41 Organ-applicator movements occurring between patient imaging and treatment delivery stages have been identified as a major source of uncertainty 33,[47][48][49][50][51][52][53] and their impact further analysed. [54][55][56][57] In cervical cancer BT, inter-and intrafraction uncertainties owing to organ movements and deformations account for 20-25% of the D 2cm3 parameter (minimum dose to the most irradiated 2 cm 3 ) per fraction and is the most essential component in the uncertainty budget for OARs.…”
Section: Treatment Errors In Btmentioning
confidence: 99%
“…Interand intrafraction deformations of prostate, bladder and rectum have been studied, [42][43][44][45][46] and the dosimetric impact owing to more general anatomical variations has been evaluated in a multicentre comparison of cervix BT. 41 Organ-applicator movements occurring between patient imaging and treatment delivery stages have been identified as a major source of uncertainty 33,[47][48][49][50][51][52][53] and their impact further analysed. [54][55][56][57] In cervical cancer BT, inter-and intrafraction uncertainties owing to organ movements and deformations account for 20-25% of the D 2cm3 parameter (minimum dose to the most irradiated 2 cm 3 ) per fraction and is the most essential component in the uncertainty budget for OARs.…”
Section: Treatment Errors In Btmentioning
confidence: 99%
“…However, depending on the institutional protocols HDR ICBT requires multiple applications. This could lead to a variation in the applicator geometry and its spatial position in relation to the pelvic organs, pelvic bony anatomy and the organs at risk [13][14][15][16][17] . These have been reported in terms of changes in the uterine axis, uterine length, slippage of tandem, colpostat separation and vaginal packing, resulting in fluctuations in spatial location of the applicator in craniocaudal axis, lateral and antero-posterior rotation as well as variation in coronal, transverse and saggital planes ( Figure 1) [18] .…”
Section: Dose Prescriptions In Hdr Era Using Point a And Icru Report 38mentioning
confidence: 99%
“…The variation in the applicator position in successive brachytherapy sessions, results in varying location of point A, as it is primarily defined in relation to the applicator itself [14,19,20] . Multiple HDR applications, thus result in different set of point As for both right and left sides, each set corresponding to each application.…”
Section: Dose Prescriptions In Hdr Era Using Point a And Icru Report 38mentioning
confidence: 99%
See 1 more Smart Citation
“…Second, geometry of the applicators changes as a consequence of the differences in vaginal packing and anatomical position of the patient. [9][10][11][12][13][14][15] As a result every parameter that influences the treatment should be thoroughly studied.…”
Section: Introductionmentioning
confidence: 99%