1995
DOI: 10.1063/1.1145464
|View full text |Cite
|
Sign up to set email alerts
|

Variable-angle ultraviolet total-internal-reflection fluorescence spectroscopy using a white excitation light source

Abstract: Articles you may be interested inA prototype of total-internal-reflection type of microphone using optical fibers J. Acoust. Soc. Am. 131, 3498 (2012); 10.1121/1.4709215High accuracy subwavelength distance measurements: A variable-angle standing-wave total-internalreflection optical microscope High volume confinement in two-photon total-internal-reflection fluorescence correlation spectroscopy Appl. Phys. Lett. 94, 083902 (2009); 10.1063/1.3077309Polyimide-waveguide-based thermal optical switch using total-int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1997
1997
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…Where detailed spectroscopic information is required from TIRF, commercial spectrouorometers are readily adapted. For most applications one of the wide range of commercially available TIRF spectrouorometer cells would be appropriate -however the literature provides examples of custom-built apparatus 47 including for specialised applications such as high pressures. 48 The main developmental thrust in TIRF imaging in recent years has been to improve the lateral resolution below the 'diffraction limit' (which is typically around 300 nm).…”
Section: Emission Spectroscopymentioning
confidence: 99%
“…Where detailed spectroscopic information is required from TIRF, commercial spectrouorometers are readily adapted. For most applications one of the wide range of commercially available TIRF spectrouorometer cells would be appropriate -however the literature provides examples of custom-built apparatus 47 including for specialised applications such as high pressures. 48 The main developmental thrust in TIRF imaging in recent years has been to improve the lateral resolution below the 'diffraction limit' (which is typically around 300 nm).…”
Section: Emission Spectroscopymentioning
confidence: 99%
“…VA-TIRF has been used to map out depth-dependent concentration profiles of fluorescein and fluorescein-labeled IgG next to surfaces [85], pyrene in thin polymer films [96], and fluorescein and acridine orange next to surfaces [97]. This method has also been used to map out the topology of cell-substrate contact regions by applying the technology to adherent cells with fluorescently labeled cytoplasms or membranes [89,94,[98][99][100][101][102][103][104].…”
Section: Variable Incidence Anglesmentioning
confidence: 99%
“…Other authors took advantage of the symmetry of a cylindrical prism [2,12,13] or used a spherical lens (J. P. Henry, personal communication). VA-EW imaging has been used to study static fluorophore distributions, dye adsorption at interfaces [14][15][16] or cell-substrate separation distances [11,[17][18][19]. For studies of dynamic processes, e.g.…”
Section: A Simple Optical Configuration For Reproducible Beam Scanningmentioning
confidence: 99%